Fatigue behaviour of titanium dental endosseous implants
In this work two different titanium dental implants are analyzed in order to evaluate their mechanical strength. An ad-hoc designed experimental apparatus is prepared to test against fatigue these implants in a way that approximates as much as possible ...
Ferdinando Felli+2 more
doaj +10 more sources
Immediate placement of endosseous implants into the extraction sockets
Implant by definition "means any object or material, such as an alloplastic substance or other tissue, which is partial or completely inserted into the body for therapeutic, diagnostic, prosthetic, or experimental purpose." The placement of a dental ...
Vijay Ebenezer+3 more
doaj +4 more sources
Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: a review and update. [PDF]
Objectives: Accidental displacement of endosseous implants into the maxillary sinus is an unusual but potential complication in implantology procedures due to the special features of the posterior aspect of the maxillary bone; there is also a ...
González-García A+4 more
europepmc +2 more sources
Custom‐made 3D printed subperiosteal implant for restoration of severe atrophic jaw: A case report [PDF]
Key Clinical Message Digital technology significantly enhances subperiosteal implantology by enabling precise presurgical planning based on CBCT scans.
Luminita Nedelcu+5 more
doaj +2 more sources
This article reports the full mouth rehabilitation of a 59-year-old male patient with completely edentulous upper and lower arches using the All-on-Six endosseous implant technique.
Gaurav Tripathi+5 more
doaj +2 more sources
Considerations regarding the osseointegration of endosseous dental implants [PDF]
Implant osseointegration has not been accepted over time, considering that in fact the implant integration is performed only in the soft tissue of the host.
Ion Pătrașcu, Bogdan Mihai Gălbinașu
doaj +1 more source
Endosseous dental implant fractures an analysis of 21 cases [PDF]
Implant fracture is an infrequent cause of implant failure. The present study evaluates 21 fractured implants, with an analysis of patient age and sex, the type, length and diameter of the implant, positioning in the dental arch, the type of prosthetic
Thet Mon Than+7 more
core +3 more sources
Immediate orthodontic load on dental implants: an option for adult treatment
The demand for orthodontic treatment in adults has been increasing. However, these patients often require a multidisciplinary approach, due to the lack of posterior teeth, requiring additional anchorage.
José Augusto Mendes Miguel+1 more
doaj +1 more source
Key Clinical Message Subperiosteal implants might be the future first‐line treatment in patients with compromised alveolar ridges, although the use of proper techniques and pre‐surgical imaging is required to ensure treatment success.
Mahnaz Arshad+2 more
doaj +1 more source
Hydroxyapatite-incorporation improves bone formation on endosseous PEEK implant in canine tibia
Background: Poly Ether Ether Ketone (PEEK) has been considered as a potential alternative material for endosseous dental implants, for its low elastic modulus, biocompatibility, and low cost in customized device manufacture.
Yuan-ming Geng+5 more
doaj +1 more source