Results 91 to 100 of about 948,742 (208)

National Trends in Open Surgical, Endovascular and Branched/Fenestrated Endovascular Aortic Aneurysm Repair in Medicare Patients

open access: yesJournal of Vascular Surgery, 2017
Background: Open repair effectively prevents rupture for patients with abdominal aortic aneurysm (AAA) and is commonly studied as a metric reflecting hospital and surgeon expertise in cardiovascular care.
B. Suckow   +7 more
semanticscholar   +1 more source

Stroke‐Heart Syndrome: Mechanisms, Temporal Phenotypes, and Diagnostic Reasoning

open access: yesAdvanced Science, EarlyView.
Stroke‐heart syndrome describes new or worsened cardiac abnormalities after acute stroke. This Review defines its clinical boundaries, traces autonomic, inflammatory, endothelial, and supply‐demand mechanisms across time, and proposes provisional phenotypes that integrate lesion location, premorbid cardiac substrate, serial biomarkers ...
Fa Lin   +13 more
wiley   +1 more source

Design, Control, and Clinical Applications of Magnetic Actuation Systems: Challenges and Opportunities

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 3, March 2025.
This review aims to provide a broad understanding for interdisciplinary researchers in engineering and clinical applications. It addresses the development and control of magnetic actuation systems (MASs) in clinical surgeries and their revolutionary effects in multiple clinical applications.
Yingxin Huo   +3 more
wiley   +1 more source

Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies

open access: yesAdvanced Intelligent Systems, EarlyView.
A unifying device–cardiovascular interface framework is presented to classify implantable cardiovascular technologies as intracardiovascular blood‐contacting systems or extracardiovascular tissue‐only and blood‐handling architectures. Cross‐class comparison across shared semiquantitative criteria, including blood‐contact burden, biomimicry ...
Bergo Nicolò   +7 more
wiley   +1 more source

Revisiting Tandler's model: Developmental anatomy of the gastrointestinal arteries and the embryological basis of human variants

open access: yesThe Anatomical Record, EarlyView.
Abstract The arterial supply of the foregut, midgut, and hindgut is commonly interpreted through the classical Tandler–Felix model, in which ventral splanchnic roots and a longitudinal anastomotic channel undergo selective persistence, regression, and remodeling.
Daniel Gondorf   +2 more
wiley   +1 more source

A Novel Anatomical Description of the Normal Terminal Fibular Artery and the Terminal Fibular Window: Radiological Findings and Surgical Implications

open access: yesClinical Anatomy, EarlyView.
ABSTRACT A novel anatomical description and radiological finding, related to the anatomical course of the terminal fibular artery (FibA) was recently reported. In the article, the authors found the terminal FibA to change its course, from being posterior and medial to the fibula to surface anteriorly and laterally before residing below the tibiofibular
Sebastian Kirdar‐Smith   +5 more
wiley   +1 more source

Superior Vena Cava Compromise During Transcatheter Atrial Septal Defect Closure: A Lesson in Implantation Geometry

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Transcatheter closure procedure of multifenestrated aneurysmal atrial septal defects (ASDs) remains technically challenging: Optimal device selection and positioning should achieve complete closure of all fenestrations while accommodating the complex three‐dimensional atrial septal anatomy and its relationship to adjacent cardiac structures ...
Pernthaler Maximilian   +3 more
wiley   +1 more source

Endovascular Abdominal Aortic Aneurysm Repair [PDF]

open access: yesCirculation, 2008
The early 1990s ushered in the era of endovascular aneurysm repair (EVAR). Diffusion of this technology, although widespread, has been met with enthusiasm by some and caution by others. Advocates of traditional open surgical techniques maintain that EVAR is costly and that long-term outcomes for patients are inferior.
Jonathan L, Eliason, Gilbert R, Upchurch
openaire   +2 more sources

Intelligent Continuum Micromachines in Complex Confined Spaces

open access: yesSmartBot, EarlyView.
The cover depicts a conceptual design for an intelligent continuum micromachine entering a target capsule used in fusion‐energy research through its slender gas‐fill tube. By combining route‐adaptive deformation, embedded sensing, and a functional end effector, the robot could inspect hidden defects, assess local conditions, and support localized ...
Huayang Sai   +7 more
wiley   +1 more source

Avaliação em médio prazo da pressão intra-saco após correção endovascular de aneurisma de aorta abdominal com o uso de sensor sem fio [PDF]

open access: yes, 2010
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Ciências Médicas.Justificativa: O objetivo do tratamento endovascular do aneurisma de aorta abdominal é a exclusão do saco ...
Lain, Vinícius Victorazzi
core  

Home - About - Disclaimer - Privacy