Results 1 to 10 of about 230,588 (168)
The approach for the modeling of corpuscular-optical systems for the analysis of charged particle flows is considered. For all the methods considered and used earlier, the condition of spatial focusing of the particle beam was required.
Arman Saulebekov, Zhanar Kambarova
doaj +1 more source
MINIATURE HIGHLY SENSITIVE ELECTRON SPECTROMETER FOR THE ANALYSIS OF CORPUSCULAR FLUXES
The work is devoted to the theoretical development of miniature highly sensitive electron spectrometer for the analysis of the composition of corpuscular flows in a wide range of measured particle energies.
A.O. Saulebekov +2 more
doaj +1 more source
Validation of Wearable Devices to Measure Energy Consumption [PDF]
OBJECTIVES The purpose of this study is to verify how accurately wearable devices measure energy expenditure while walking outdoors. METHODS A total of 20 people, 10 healthy males and 10 females, participated in the study.
Ji-Soo Ryu, Jung-Jun Park
doaj +1 more source
Energy Analyzer Emulation for Energy Management Simulators [PDF]
The simulation of microgrids to testing and validate energy management methodologies are an important step to take before the massive implementation of microgrids. However, microgrids are usually unavailable for R&D centers to perform tests and validations. To solve this issue is important to get the simulations closer to the reality, using real energy
Gomes, Luis, Vale, Zita
openaire +2 more sources
"THE HIGH-RESOLUTION ELECTROSTATIC ENERGY ANALYZER FOR SPACE RESEARCH "
The energy analyzer of charged particle beams for space research is proposed. The developed electron-optical scheme of the energy analyzer of the charged particle beam is built on the basis of the electrostatic decapole-cylindrical field.
А.О. Saulebekov +2 more
doaj +1 more source
Calculation of the electron-optical scheme of a new type mirror energy analyzer of charged particles [PDF]
Further studies of the electron-optical properties of electrostatic multipole-cylindrical fields, synthesized from the fields of a cylindrical mirror and circular multipoles, are continued in the work. The implementation of electron spectroscopy methods
Ж.Т. Камбарова +2 more
doaj +2 more sources
INFLUENCE OF HEAT TREATMENT ON THE CONDITION OF THIN-FILM SYSTEM Cr + Ni ON SILICON
Using Auger electron spectroscopy, an experimental study of the Si – Cr – Ni system was carried out. A comparative analysis of the results before and after exposure to thermal shock at the interfaces showed the effect of temperature on the distribution ...
O.G. Ashkhotov +3 more
doaj +1 more source
Development of energy analyzer of charged particles
The electron-optical characteristics of a mirror energy analyzer based on a non-uniform, hyperbolic decreasing electrostatic field were investigated.
А.О. Saulebekov +5 more
doaj +1 more source
An existing cylindrical mirror analyzer (CMA) that was initially equipped with eight channeltrons detectors has been modified to install large micro-channel plate detectors to perform parallel detection of electrons on an energy range corresponding to ...
Francis Penent +7 more
doaj +1 more source
Analyzing feasibility of energy storage system for energy arbitrage
The need for integration of renewable energy to the electricity grid promotes research and development of new energy storage technologies, as well as models and techniques to study them. In this sense, the present work proposes a model to evaluate the benefit that can be harnessed through energy arbitrage in function of a daily hourly rate ...
Buzarquis Ríos, Enrique Hazam Mohammed +2 more
openaire +2 more sources

