Results 221 to 230 of about 685,502 (357)

Micropatterned Biphasic Printed Electrodes for High‐Fidelity on‐Skin Bioelectronics

open access: yesAdvanced Functional Materials, EarlyView.
Micropatterned biphasic printed electrodes achieve unprecedented skin conformity and low impedance by combining liquid‐metal droplets with microstructured 3D lattices. This scalable approach enables high‐fidelity detection of ECG, EMG, and EEG signals, including alpha rhythms from the forehead, with long‐term comfort and stability.
Manuel Reis Carneiro   +4 more
wiley   +1 more source

Modelling the impact of social network on energy savings

open access: hybrid, 2016
Feng Du   +5 more
openalex   +1 more source

Flux‐Regulated Crystallization of Perovskites Using Machine Learning‐Predicted Solvent Evaporation Rates for X‐Ray Detectors

open access: yesAdvanced Functional Materials, EarlyView.
By integrating machine learning into flux‐regulated crystallization (FRC), accurate prediction of solvent evaporation rates in real time, improving crystallization control and reducing crystal growth variability by over threefold, is achieved. This enhances the reproducibility and quality of perovskite single crystals, leading to reproducible ...
Tatiane Pretto   +8 more
wiley   +1 more source

The Influence of Annealing on the Sb Layer in the Synthesis of [001]‐Oriented Sb2Se3 Film for Photoelectrochemical Hydrogen Gas Generation

open access: yesAdvanced Functional Materials, EarlyView.
[001]‐oriented Sb2Se3 film with improved crystallinity and adjusted composition is achieved via a new thermal treatment approach consisting of preliminary annealing of the Sb layer before its selenization. The findings of this work demonstrate enhanced charge carriers' transportation, a stable performance, and an improvement of H2 generation from ...
Magno B. Costa   +7 more
wiley   +1 more source

Printed Integrated Logic Circuits Based on Chitosan‐Gated Organic Transistors for Future Edible Systems

open access: yesAdvanced Functional Materials, EarlyView.
Edible electronics needs integrated logic circuits for computation and control. This work presents a potentially edible printed chitosan‐gated transistor with a design optimized for integration in circuits. Its implementation in integrated logic gates and circuits operating at low voltage (0.7 V) is demonstrated, as well as the compatibility with an ...
Giulia Coco   +8 more
wiley   +1 more source

Long-term Energy and Emissions Savings Potential in New York City Buildings

open access: green, 2012
Vatsal Bhatt   +4 more
openalex   +2 more sources

Biodegradable and Recyclable Luminescent Mixed‐Matrix‐Membranes, Hydrogels, and Cryogels based on Nanoscale Metal‐Organic Frameworks and Biopolymers

open access: yesAdvanced Functional Materials, EarlyView.
The study presents biodegradable and recyclable mixed‐matrix membranes (MMMs), hydrogels, and cryogels using luminescent nanoscale metal‐organic frameworks (nMOFs) and biopolymers. These bio‐nMOF‐MMMs combine europium‐based nMOFs as probes for the status of the materials with the biopolymers agar and gelatine and present alternatives to conventional ...
Moritz Maxeiner   +4 more
wiley   +1 more source

Double Helical Plasmonic Antennas

open access: yesAdvanced Functional Materials, EarlyView.
Plasmonic double helical antennas funnel circularly polarized light to the nanoscale, offering strong chiroptical interaction and directional light emission. Extending a single helix design tool, this study combines numerical modeling with experimental validation, revealing large, broadband dissymmetry factors in the visible range.
Aleksei Tsarapkin   +7 more
wiley   +1 more source

Highly Sensitive Electrochemical Biosensor Based on Hairy Particles with Controllable High Enzyme Loading and Activity

open access: yesAdvanced Functional Materials, EarlyView.
For the first time, a highly sensitive electrochemical biosensor based on SiO2‐based hairy particles with a grafted PDMAEMA polymer brush containing a quantifiable and large amount of immobilized Laccase is reported. The fabricated biosensor exhibits a sensitivity of 0.14 A·m⁻¹, a limit of detection (LOD) of 0.1 µm, and a detection range of 0.3–750 µm,
Pavel Milkin   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy