Results 171 to 180 of about 6,223 (218)

Recyclable quasi-solid-state dynamic windows via reversible dual-metal electrodeposition for building energy modulation. [PDF]

open access: yesNat Commun
Xu B   +10 more
europepmc   +1 more source

EnergyPlus models for the benchmarking of residential buildings in Brunei Darussalam

Energy and Buildings, 2018
Abstract Energy performance of buildings is a highly important measure for Energy Efficiency and Conservation initiatives. The fundamental step toward the understanding of energy use is benchmarking. In this study, the EnergyPlus simulation tool is used to benchmark the energy performance of 400 residential buildings from which three types of ...
S Mathew
exaly   +2 more sources

EnergyPlus Simulation Speedup Using Data Parallelization Concept

open access: yesASME 2010 4th International Conference on Energy Sustainability, Volume 2, 2010
EnergyPlus is an energy simulation tool which models heating, cooling, lighting, ventilation, and other energy flows in buildings. It is based on the popular features of BLAST and DOE-2. Though EnergyPlus is more advanced than DOE-2, it comes with a drawback of larger simulation runtime. A decrease in the simulation runtime of EnergyPlus would increase
Vishal Garg   +3 more
openaire   +2 more sources

Building Energy Performance: Comparison Between EnergyPlus and Other Certified Tools

open access: yes, 2021
Currently, the energy consumption study in buildings is critical in fulfilling the EU objectives to achieve carbon neutrality. There are several building energy simulation tools and other spreadsheets available on the market. One of the main software tools, the EnergyPlus software, and two Excel spreadsheets developed in Portugal to assess the thermal ...
Diogo Esteves   +4 more
openaire   +3 more sources

Impact of Civil Envelope on Energy Consumption based on EnergyPlus

open access: yesProcedia Engineering, 2015
In this paper, a rural residential model located in Shenyang is established by simulation software DesignBuilder. Simulation process is divided into the following conditions, variety of thermal performance walls, roofs and windows.
Shui Yu, Guohui Feng
exaly   +2 more sources

Building HVAC load profiling using EnergyPlus

2015 IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA), 2015
Building load profiling plays an important part in the development of optimal energy management systems. Heating, Ventilation, Air Conditioning (HVAC) systems consume around 40% to 50% of the total energy consumed by buildings. Using this load data, optimal operation scheduling can be determined to reduce the peak energy requirement and minimize the ...
Ujjal Manandhar, Abhisek Ukil, Dong Wang
openaire   +1 more source

Home - About - Disclaimer - Privacy