Results 11 to 20 of about 1,228 (148)

Modelado urbano microclimático para la simulación termo-energética de viviendas en edificios en altura en Mendoza, Argentina. Integración del software ENVI-met y EnergyPlus

open access: yesInformes de la Construccion, 2021
La ciudad de Mendoza, Argentina, cuenta con una intensa forestación urbana que definen dos estratos en altura: bajo y sobre la copa de los árboles. En este contexto, el comportamiento térmico de viviendas en altura estará afectado según el ambiente ...
Julieta Balter   +3 more
doaj   +1 more source

Vertikalne fasade solitera kao lokacije za instalaciju fotonaponskih panela

open access: yesEnergija, Ekonomija, Ekologija, 2022
Fasade solitera predstavljaju alternativnu lokaciju za instalaciju fotonaponskih panela, koji se najčešće postavljaju na krovove objekata. Specifičan prostorni oblik solitera, sa relativno malom površinom osnove u odnosu na visinu objekata, pruža ...
Andreja Stefanović
doaj   +1 more source

EnergyPlus Run Time Analysis [PDF]

open access: yes, 2008
EnergyPlus is a new generation building performance simulation program offering many new modeling capabilities and more accurate performance calculations integrating building components in sub-hourly time steps. However, EnergyPlus runs much slower than the current generation simulation programs.
Hong, Tianzhen   +2 more
openaire   +2 more sources

Redução De Consumo De Energia Elétrica Através De Conceitos Green Building

open access: yesEletrônica de Potência, 2009
Nos últimos anos, as alterações na estrutura do setor elétrico e o aumento do valor das tarifas fez com que fossem desenvolvidos programas e projetos visando a estabelecer uma nova conscientização para o uso eficiente da energia elétrica.
Maria Fernanda Martinez   +3 more
doaj   +1 more source

Numerička analiza toplotnih performansi geotermalne toplotne pumpe za potrebe grejanja i hlađenja stambene zgrade

open access: yesEnergija, Ekonomija, Ekologija, 2023
U ovom radu izvršena je numerička analiza (uz korišćenje softvera EnergyPlus) primene geotermalne toplotne pumpe za grejanje i hlađenje trospratne stambene zgrade locirane u Kragujevcu.
Aleksa Savić   +5 more
doaj   +1 more source

Development of Virtual Human Agents with Different Thermal Preferences for Energy and Thermal Comfort Simulation [PDF]

open access: yesE3S Web of Conferences, 2023
Researchers have used building energy simulation tools such as EnergyPlus to evaluate building energy and occupant thermal preference. EnergyPlus is a powerful tool for modeling buildings, However, when controlling the indoor set temperature using ...
Jeong Bonghoon   +3 more
doaj   +1 more source

Optimal orientation of the gable roofs covered with photovoltaic panels: Case study Kragujevac [PDF]

open access: yesTehnika, 2023
In this paper, a study was conducted to determine the optimal orientation of the gable roofs covered with photovoltaic panels (PVP) for the area of the city of Kragujevac.
Jovanović Davor N.   +1 more
doaj  

Novel Simulation Algorithm for Modeling the Hysteresis of Phase Change Materials

open access: yesEnergies, 2020
Latent heat thermal energy storage (LHTES) using phase change materials (PCM) is one of the most promising ways for thermal energy storage (TES), especially in lightweight buildings. However, accurate control of the phase transition of PCM is not easy to
Anna Zastawna-Rumin   +2 more
doaj   +1 more source

Occupant-oriented mixed-mode EnergyPlus predictive control simulation [PDF]

open access: yesEnergy and Buildings, 2016
Model predictive control (MPC) has been studied in the building science realm for about three decades. However, the following two aspects of the building control have not been studied thoroughly in MPC research. One is the impact of the mixed-mode cooling system on the active heating ventilation and air conditioning (HVAC) energy consumption, and the ...
Jie Zhao   +3 more
openaire   +1 more source

Simulation case study of stack pressure impact on thermal load in high-rise buildings [PDF]

open access: yesE3S Web of Conferences, 2023
The reference building models in the EnergyPlus tool do not consider the stack effect. This is not an issue for small and low-rise buildings. However, this is significant in evaluating the heating and cooling load of high-rise buildings.
Joe Jaewan   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy