Results 11 to 20 of about 6,223 (218)
EnergyPlus Run Time Analysis [PDF]
EnergyPlus is a new generation building performance simulation program offering many new modeling capabilities and more accurate performance calculations integrating building components in sub-hourly time steps. However, EnergyPlus runs much slower than the current generation simulation programs.
Hong, Tianzhen +2 more
openaire +3 more sources
EnergyPlus Run Time Analysis [PDF]
EnergyPlus is a new generation building performance simulation program offering many new modeling capabilities and more accurate performance calculations integrating building components in sub-hourly time steps. However, EnergyPlus runs much slower than the current generation simulation programs.
Hong, Tianzhen
openaire +2 more sources
Advancement of DOE's EnergyPlus Building Energy Simulation Payment [PDF]
EnergyPlus{sup TM} is a new generation computer software analysis tool that has been developed, tested, and commercialized to support DOEâs Building Technologies (BT) Program in terms of whole-building, component, and systems R&D (http://www.energyplus.gov). It is also being used to support evaluation and decision making of zero energy building (ZEB)
Gu, Lixing +12 more
openaire +3 more sources
Implementation of EnergyPlus Objects in SAPTool
In the scope of the Ren4EEnIEQ project (https://ren4eenieq.wordpress.com/) a comprehensive BIM add-on tool for the improvement of energy efficiency and indoor environment quality in renovation of buildings (SAPTool) was developed. This tool – developed in Java – allows to produce alternative building geometries, from the same user requirements and ...
Fernandes, Marco
openaire +2 more sources
PERFORMANCE OF DIFFERENT PHOTOVOLTAIC MODELS IN ENERGYPLUS ENVIRONMENT [PDF]
Zero net energy building uses photovoltaic (PV) panels for electricity generation from solar energy. To calculate the annual electricity generation, the EnergyPlus software is used. The EnergyPlus software contains three models of PV panels: Simple, Equivalent One-Diode and Sandia.
Radulović, Jasna +4 more
openaire +2 more sources
Hoonete energiaarvutused tarkvara EnergyPlus abil [PDF]
http://tartu.ester.ee/record=b2655993~S1 ...
Smolin, Ivar
openaire +2 more sources
The paper aims to explore the effect of different passive cooling measures using thermal modelling and predicting. Solar shading, green roofs and cool paints were incorporated as passive cooling measures to evaluate their combined effects on indoor ...
Oluwatimilehin P. Olawale-Johnson +2 more
doaj +1 more source
On-Site Generation Simulation with EnergyPlus for Commercial Buildings [PDF]
Building energy simulation software (e.g., EnergyPlus) is a powerful tool used widely by designers and researchers. However, current software is limited in modeling distributed generation (DG), including DG with heat recovery applied to building end-use, i.e., combined heat and power (CHP). Concurrently, DG investment and dispatch optimization software
Stadler, Michael +3 more
openaire +2 more sources
Sensitivity analysis of medical centers energy consumption with EnergyPlus [PDF]
Sensitivity analysis plays a vital role in building energy analysis. It is done to clarify which are the crucial variables affecting building thermal performance and to evaluate quantitatively those effects. It can be conducted both through energy simulation models and real case observations.
Soroush Rastegarpour +4 more
openaire +1 more source
Analysis of the potential use of Trombe walls in Brazil: design recommendations
In this paper, the thermal performance of a standard environment was evaluated based on the use of a Trombe wall with different configurations and types of use, as the potential for using this passive strategy is still little studied in Brazil.
de Melo Sá Cavalcanti Fernando Antonio +1 more
doaj +1 more source