Results 71 to 80 of about 8,773 (170)
Interoperability between Autodesk Revit and EnergyPlus for thermal simulations of buildings
This article aims to analyze the reliability of the interoperability possibilities between Autodesk Revit and EnergyPlus by using BIM models for thermal simulations in EnergyPlus.
Gabriel Ramos de Queiróz +2 more
doaj +1 more source
Dimensionamento de área de janela em edificações comerciais: integração da iluminação natural com a artificial e utilização da ventilação híbrida [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia CivilO objetivo deste trabalho é desenvolver um método para prédimensionar área de janela baseado no consumo de energia elétrica ...
Rupp, Ricardo Forgiarini
core
Conventional passive radiative cooling films rely on costly feedstocks and energy‐intensive fabrication, with poor end‐of‐life compatibility in agriculture. To address this challenge, a sustainable radiative cooling mulch (SRCM) is developed from waste maize leaves via spontaneous hydrogen‐bond self‐assembly.
Hao Li +13 more
wiley +1 more source
A influência da luz natural na avaliação da eficiência energética de edifícios contemporâneos de escritórios em Florianópolis/SC [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2009Muitas edificações desperdiçam relevantes oportunidades de poupar energia, por não considerar ...
Didoné, Evelise Leite
core
A scalable, color‐adaptive radiative cooling coating is developed to enable dynamic spectral regulation via a reversible thermochromic transition at ~45 °C and a high solar reflectance of 91.7%. The coating achieves 4.44 °C outdoor sub‐ambient cooling while providing robust superhydrophobicity and environmental durability through its micro/nano ...
Ziqi Li +8 more
wiley +1 more source
Graph Neural Network‐Based Prediction of Building Energy Consumption
A graph neural network that encodes a multi‐zone building as a graph accurately predicts hourly cooling and heating loads across three distinct climates, outperforming Random Forest and XGBoost baselines and serving as a fast surrogate to EnergyPlus simulations for scalable building energy management.
Ali Maboudi Reveshti +4 more
wiley +1 more source
Novel Parameterization of Building Storage Heat Flux for Urban Climate Modeling
Abstract Accurate estimation of building heat storage flux (ΔQS) is essential for modeling the urban surface energy balance and urban climates. The Objective Hysteresis Model (OHM) is a computationally efficient scheme that uses coefficients (a1, a2, a3) that can be derived from standard thermal parameters for heat conduction.
Yiqing Liu +4 more
wiley +1 more source
EnergyPlus Energy Simulation Software [PDF]
Undergraduate Research Opportunities Program, University of Minnesota DuluthGerber, Michael. (2014). EnergyPlus Energy Simulation Software.
Gerber, Michael
core
Simulation of Energy Management Systems in EnergyPlus [PDF]
An energy management system (EMS) is a dedicated computer that can be programmed to control all of a building's energy-related systems, including heating, cooling, ventilation, hot water, interior lighting, exterior lighting, on-site power generation ...
Torcellini, P. A. +2 more
core
Impact of ventilation stacks on airflow in naturally ventilated buildings: Simulation vs. measurements [PDF]
Modeling of mass and energy flows in naturally ventilated buildings enables the prediction of indoor thermal conditions and the evaluation of ventilation performance under different operational scenarios.
Grygierek Krzysztof +1 more
doaj +1 more source