Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method

open access: yes, 2015
In vivo dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by ...
Yoon, JiHyung
core  

A component-wise commissioning and validation framework for non-transit electronic portal imaging device patient-specific quality assurance. [PDF]

open access: yesPhys Imaging Radiat Oncol
Moghaddasi L   +7 more
europepmc   +1 more source

Direct dose to water dosimetry for pretreatment IMRT verification using a modified EPID

open access: yes, 2011
Purpose: Electronic portal imaging devices (EPIDs) are high resolution systems that produce electronic dose maps with minimal time required for equipment setup, and therefore potentially present a time-saving alternative for intensity modulated ...
Baldock, C (15601538)   +5 more
core  

A multi-institutional EPID-based 3D dose reconstruction model in a virtual phantom for standardized patient QA, benchmarking and auditing for stereotactic radiosurgery. [PDF]

open access: yesPhys Imaging Radiat Oncol
Zwan B   +19 more
europepmc   +1 more source

Sensitivity and concordance study of an open source EPID-based linear accelerator test suite. [PDF]

open access: yesJ Appl Clin Med Phys
Critchfield LC   +14 more
europepmc   +1 more source

A comparison of a novel prototype electronic portal imaging device (EPID) with film and commercial epids

open access: yesInternational Journal of Radiation Oncology*Biology*Physics, 1998
Sanjiv S. Samant   +3 more
openaire   +1 more source

Beam-axis stability during gantry rotation measured with scintillation dosimetry. [PDF]

open access: yesJ Appl Clin Med Phys
Ohira S   +9 more
europepmc   +1 more source

COMP Report: Patient-specific quality assurance practices in Canadian radiotherapy-results from a national survey. [PDF]

open access: yesJ Appl Clin Med Phys
Tran MN   +7 more
europepmc   +1 more source

An improved Monte-Carlo model of the varian EPID separating support arm and rear-housing backscatter

open access: yes
Previous investigators of EPID dosimetric properties have ascribed the backscatter, that contaminates dosimetric EPID images, to its supporting arm. Accordingly, Monte-Carlo (MC) EPID models have approximated the backscatter signal from the layers under ...
Peter Greer (21132713)   +2 more
core  