Setup Error Differences and Margin Expansion Among Rectal Cancer Segments: Consistency Evaluation Between EPID and iSCOUT [PDF]
Purpose To analyze the differences in setup errors among patients with rectal cancer in the upper, middle and lower segments and evaluate the consistency between electronic portal imaging device (EPID) and iSCOUT imageāguided techniques.
Bao Wan +10 more
doaj +2 more sources
Dose Characteristics of a Deep Learning Model for EPID-based In vivo Dosimetry [PDF]
Background: Images from onboard electronic portal imaging devices (EPID) contain dose information that can be converted into dose maps. A cycle-consistent generative adversarial network (CycleGAN)-based model was developed for two-dimensional (2D) EPID ...
Qilin Li +4 more
doaj +2 more sources
Catching errors with in vivo EPID dosimetry
The potential for detrimental incidents and the ever increasing complexity of patient treatments emphasize the need for accurate dosimetric verification in radiotherapy. For this reason, all curative treatments are verified, either pretreatment or in vivo, by electronic portal imaging device (EPID) dosimetry in the Radiation Oncology Department of the ...
Van Herk, Marcel; id_orcid 0000-0001-6448-898X +9 more
openaire +5 more sources
Reporting Clinical Results of EPID-Based Patient-Specific Quality Assurance for Brain Stereotactic Radiosurgery/Radiation Therapy: Demonstrating the Feasibility of Same-Day Stereotactic Radiosurgery via HyperArc Delivery [PDF]
Purpose: Patient-specific quality assurance (PSQA) of complex volumetric modulated arc therapy plans via Electronic portal imaging device (EPID)-based portal dosimetry (PD) is widely adopted by the radiation therapy community.
Damodar Pokhrel, PhD +3 more
doaj +2 more sources
Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study [PDF]
Introduction: This research is a preliminary study of the development of Artificial Intelligence (AI) as a conversion tool from the pixel value of Cine a-Si 1000 Electronic Portal Imaging Device (EPID) images to dose.
Muhammad Ramadhan +2 more
doaj +1 more source
Development of an Electronic Portal Imaging Device Dosimetry Method
Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter ...
Jun Zhang +4 more
doaj +1 more source
Clinical Experience of Intensity Modulated Radiotherapy Pre-Treatment Quality Assurance for Carcinoma Head and Neck Patients with EPID and IMatriXX in Rural Center [PDF]
Background: Radiation therapy techniques as Intensity Modulated Radiotherapy (IMRT), rapid arc have been used for treatment of cancer with high accuracy.
M More, V Jain, O P Gurjar
doaj +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source