Results 151 to 160 of about 8,606 (195)
Electronic portal imaging detectors (EPID) have initially been developed for imaging purposes but they also present a great potential for dosimetry. This is of special interest for intensity modulated radiation treatment (IMRT), where the complexity of ...
Andrew Fielding +2 more
exaly +2 more sources
EPID dosimetry – configuration and pre-treatment IMRT verification [PDF]
SummaryBackgroundThe electronic portal imaging device (EPID) is used for patient setup during radiotherapy sessions. Dosimetric verification is done using ion chambers, diodes and thermoluminescence detectors.
Krzysztof Šlosárek +1 more
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Medical physics, 2012
Item does not contain ...
Van Herk, Marcel; id_orcid 0000-0001-6448-898X +9 more
openaire +2 more sources
Item does not contain ...
Van Herk, Marcel; id_orcid 0000-0001-6448-898X +9 more
openaire +2 more sources
Displays, 2006
Electrophoretic image displays (EPIDs) are a very promising solution in the search for low-power, paper like reflective displays. While the technology is already mature, little is known about the internal physical properties. In this paper, we will describe which elements contribute to the charge transport and give an explanation of the steady state ...
Tom Bert +3 more
openaire +3 more sources
Electrophoretic image displays (EPIDs) are a very promising solution in the search for low-power, paper like reflective displays. While the technology is already mature, little is known about the internal physical properties. In this paper, we will describe which elements contribute to the charge transport and give an explanation of the steady state ...
Tom Bert +3 more
openaire +3 more sources
Medical Physics, 2001
There has been an increasing interest in the application of electronic portal imaging devices (EPIDs) to dosimetric verification, particularly for intensity modulated radiotherapy. Although not water equivalent, the phantom scatter factor of an EPID, is generally assumed to be that of a full phantom, a slab phantom, or a mini phantom.
J, Chang +3 more
openaire +2 more sources
There has been an increasing interest in the application of electronic portal imaging devices (EPIDs) to dosimetric verification, particularly for intensity modulated radiotherapy. Although not water equivalent, the phantom scatter factor of an EPID, is generally assumed to be that of a full phantom, a slab phantom, or a mini phantom.
J, Chang +3 more
openaire +2 more sources
WE‐G‐BRB‐02: MU‐EPID an EPID Based Tool for IMRT Quality Assurance
Medical Physics, 2012Purpose: A software program (MU‐EPID) has been developed to perform patient specific IMRT pre‐treatment QA verification using an electronic portal imaging device. Methods: The software converts measured images of intensity modulated beams delivered to an EPID, into fluence maps that can be imported in the treatment planning system. The dose can then be
L Vazquez, Quino +5 more
openaire +2 more sources
Generalized EPID calibration for in vivo transit dosimetry
Physica Medica, 2011Many researchers are studying new in vivo dosimetry methods based on the use of Elelctronic portal imaging devices (EPIDs) that are simple and efficient in their daily use. However the need of time consuming implementation measurements with solid water phantoms for the in vivo dosimetry implementation can discourage someone in their use.
Andrea, Fidanzio +6 more
openaire +3 more sources
Radiotherapy and Oncology, 2009
The complexity of radiotherapy today demands thorough verification of the dose delivered to the patient. Dosimetry using electronic portal imaging devices (EPIDs) has received considerable attention recently, since with this method dose verification can be performed accurately and efficiently, both pre-treatment and in vivo.
openaire +1 more source
The complexity of radiotherapy today demands thorough verification of the dose delivered to the patient. Dosimetry using electronic portal imaging devices (EPIDs) has received considerable attention recently, since with this method dose verification can be performed accurately and efficiently, both pre-treatment and in vivo.
openaire +1 more source
2018
Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions.
Mohammadi, Mahdi, Haghparast, Abbas
openaire +1 more source
Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions.
Mohammadi, Mahdi, Haghparast, Abbas
openaire +1 more source
In vivo dosimetry by an aSi‐based EPID
Medical Physics, 2006A method for the in vivo determination of the isocenter dose, , and mid‐plane dose, , using the transmitted signal measured by 25 central pixels of an aSi‐based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated ...
Angelo, Piermattei +10 more
openaire +2 more sources