EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams [PDF]
We proposed to perform a basic dosimetry commissioning on a new imager system, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter‐free (FFF) beams, then to develop an image‐based quality assurance (QA) model for verification of the system delivery accuracy for intensity‐
Miri, Narges +3 more
openaire +2 more sources
The dose delivery verification for a head and neck static intensity modulated radiation therapy (IMRT) case using a scanning liquid ionization chamber electronic portal imaging device (SLIC-EPID) was investigated.
Mohammad Mohammadi, Eva Bezak
doaj +1 more source
PURPOSE:The goal of this study was to investigate the effectiveness of monitoring relevant variations during treatments for electronic portal imaging device (EPID)-based 3D in vivo verification performed using planning CTs.
Yinghui Li +4 more
doaj +1 more source
Radiotherapy is one of common treatment modality for Nasopharyngeal Cancer. The development of intensity modulated radiotherapy (IMRT technique) gives satisfactory results in the nasopharyngeal cancer treatment, both clinically and dosimetry.
SUSI NOFRIDIANITA
doaj +1 more source
EPID with Efficient Proof of Non-Revocation
EPID systems are anonymous authentication mechanisms which are standardized by ISO/IEC and massively deployed in Intel processors. They are related to the large family of privacy-preserving signatures but differ in that they provide a very pragmatic way of revoking members.
openaire +2 more sources
Comparison of electronic portal imaging device-based Winston–Lutz analysis software
Background: Stereotactic radiosurgery (SRS) with a linear accelerator requires submillimetre geometric accuracy. The Winston–Lutz (WL) test verifies coincidence among radiation, mechanical, and imaging isocentres.
Hein Fourie +2 more
doaj +1 more source
EPID-Based Setup Error Correction in Head and Neck Radiotherapy [PDF]
Introduction: This study introduces and evaluates a novel optimized averaging method for Electronic Portal Imaging Device (EPID)-based setup corrections, comparing it with conventional approaches.
Mohamad Pursamimi +5 more
doaj +1 more source
Dose calibration of EPIDs for segmented IMRT dosimetry [PDF]
The purpose of this study was to investigate the dose response of amorphous silicon (a‐Si) electronic portal imaging devices (EPIDs) under different acquisition settings for both open jaw defined fields and segmented intensity‐modulated radiation therapy (IMRT) fields. Four different EPIDs were used.
Deshpande, S +4 more
openaire +3 more sources
EPID – a useful interfraction QC tool
Abstract Biomedical accelerators used in radiotherapy are equipped with detector arrays which are commonly used to obtain the image of patient position during the treatment session. These devices use both kilovolt and megavolt x-ray beams.
Klimas, Aleksandra +9 more
openaire +3 more sources
Diverse Uses of Lantibiotics: Exploring New Approaches to Combat Antibiotic Resistance
This review illustrates lantibiotics as an alternative therapeutic approach to combat antibiotic resistance, highlighting their diverse sources, including plants, insects, animals, and microorganisms. It further emphasizes their broad therapeutic potential, including antibacterial, antifungal, antiparasitic, antiviral, and anticancer activities (GA ...