Results 171 to 180 of about 7,739 (203)
Some of the next articles are maybe not open access.

Compensator quality control with an amorphous silicon EPID

Medical Physics, 2003
The calibration and quality control of compensators is conventionally performed with an ion chamber in a water‐equivalent phantom. In our center, the compensator factor and four off‐axis fluence ratios are measured to verify the central axis beam modulation and orientation of the compensator. Here we report the investigation of an alternative technique
Geetha V, Menon, Ron S, Sloboda
openaire   +2 more sources

Characterization of EPID software for VMAT transit dosimetry

Australasian Physical & Engineering Sciences in Medicine, 2018
Dosimetry check (DC) is a commercial software that allows reconstruction of 3D dose distributions using transit electronic portal imaging device (EPID) images. In this work, we evaluated the suitability of DC software for volumetric modulated arc therapy (VMAT) transit dosimetry.
Marco Esposito   +6 more
openaire   +2 more sources

Dose‐response characteristics of an amorphous silicon EPID

Medical Physics, 2005
Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac‐specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose‐response behavior. The aim of
Peter, Winkler   +2 more
openaire   +2 more sources

Dosimetric IMRT verification with a flat‐panel EPID

Medical Physics, 2003
A convolution‐based calibration procedure has been developed to use an amorphous silicon flat‐panel electronic portal imaging device (EPID) for accurate dosimetric verification of intensity‐modulated radiotherapy (IMRT) treatments. Raw EPID images were deconvolved to accurate, high‐resolution 2‐D distributions of primary fluence using a scatter kernel ...
B, Warkentin   +3 more
openaire   +2 more sources

Simplifying EPID dosimetry for IMRT treatment verification

Medical Physics, 2011
Purpose:Electronic portal imaging devices (EPIDs) are increasingly used for IMRT dose verification, both pretreatment andin vivo. In this study, an earlier developed backprojection model has been modified to avoid the need for patient‐specific transmission measurements and, consequently, leads to a faster procedure.Methods:Currently, the transmission ...
Van Herk, Marcel; id_orcid 0000-0001-6448-898X   +7 more
openaire   +3 more sources

Comparison of ghosting effects for three commercial EPIDs

Medical Physics, 2006
Many studies have reported dosimetric characteristics of amorphous silicon electronic portal imaging devices (EPIDs). Some studies ascribed a non‐linear signal to gain ghosting and image lag. Other reports, however, state the effect is negligible. This study compares the signal‐to‐monitor unit (MU) ratio for three different brands of EPID systems.
Van Herk, Marcel; id_orcid 0000-0001-6448-898X   +6 more
openaire   +5 more sources

Epid Dosimetry

AIP Conference Proceedings, 2011
Peter B. Greer   +5 more
openaire   +1 more source

EPID-Based Dosimetry

2021
Brayden Schott   +3 more
openaire   +1 more source

A MODEL OF EPID SUPPORT ARM BACKSCATTER FOR IMPROVED IMRT AND ARC-IMRT VERIFICATION WITH EPID

Radiotherapy and Oncology, 2009
P. Rowshan-Farzad   +3 more
openaire   +1 more source