Results 91 to 100 of about 8,715 (199)
ObjectiveA quality control (QC) system based on the electronic portal imaging device (EPID) system was used to realize the Multi-Leaf Collimator (MLC) position verification and dose verification functions on Primus and VenusX accelerators.
Jianfeng SUI +5 more
doaj +1 more source
Tumor displacement measured with reference to the first EPID image acquired at the first session.
EPID = electronic portal imaging device.
Akiko Semba (656395) +6 more
core +1 more source
EPIDs and QA of advanced treatments
Abstract In this paper I will summarize the various possibilities of EPIDs for their use as tools for QA of advanced treatments. After elucidating the choice of EPIDs for this purpose, I will review the use of EPIDs for pre-treatment and in vivo (transit) dosimetry applications.
openaire +1 more source
ntroducción: El cáncer de pulmón (CP) es una comorbilidad importante que puede complicar el pronóstico de los pacientes con EPID. En 2018, la European Respiratory Society (ERS) propuso una nueva forma de clasificación de la EPID, según su tendencia a ...
Martínez García, María de los Ángeles
core +1 more source
Determination of EPID convolution kernels for portal imaging using carbon target bremsstrahlung
Improving the accuracy and reproducibility during patient positioning is of paramount importance. Hence, the goal of this work is to characterize the aspects of image blurring occurring during carbon target bremsstrahlung portal imaging and to assess the
Lüdeke Sascha +5 more
doaj +1 more source
Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT).
Henzen, Dominik +24 more
core +1 more source
Comparison of PID and EPID controllers in self balancing robot
Two wheeled Self balancing robots have become more popular in recent times and used in many applications, commonly used in transportation as these balancing robots are faster and apparently stable. Balancing is achieved by using controllers tuned for the
AKPOLAT, ALPER NABİ
core +1 more source
Performance optimization of the Varian aS500 EPID system
Today, electronic portal imaging devices (EPIDs) are widely used as a replacement to portal films for patient position verification, but the image quality is not always optimal. The general aim of this study was to optimize the acquisition parameters of an amorphous silicon EPID commercially available for clinical use in radiation therapy with the view
Berger, Lucie +3 more
openaire +2 more sources
In vivo dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by ...
NC DOCKS at East Carolina University +1 more
core
This work assessed the dosimetric performance of an amorphous silicon electronic portal imaging device (EPID) for measurement and quality assurance of enhanced dynamic wedge (EDW) profile and wedge factor. EPID measurements of EDW profiles were corrected
Michael P. Barnes (21274832) +1 more
core

