Gamma failure rate statistics of pure EPID reconstruction, CBCT-guided EPID reconstruction and TPS simulation for thoracic Phantom shift.
Yinghui Li (237776) +4 more
core +1 more source
Super-resolution imaging in a multiple layer EPID [PDF]
Abstract A new portal imager consisting of four vertically stacked conventional electronic portal imaging device layers has been constructed in pursuit of improved detective quantum efficiency. We hypothesize that super-resolution (SR) imaging can also be achieved in such a system by shifting each layer laterally ...
Haijian, Chen +7 more
openaire +2 more sources
Evaluation of Perkin Elmer Amorphous Silicon Electronic Portal Imaging Device for Small Photon Field Dosimetry [PDF]
Background: Electronic portal imaging devices (EPIDs) are applied to measure the dose and verify patients’ position.Objective: The present study aims to evaluate the performance of EPID for measuring dosimetric parameters in small photon fields.Material ...
Mohammad Haghparast +4 more
doaj +1 more source
Abstract This response to Alister McGrath’s The Nature of Christian Doctrine examines the interplay between Scripture, the Rule of Faith, and evolving Christian doctrine and tradition. Focusing on McGrath’s critique of Lindbeck’s presentation of doctrinal modalities, the article explores how doctrinal formation involves primarily synchronic (canonical),
Tomas Bokedal
wiley +1 more source
Sensitivity of an Elekta iView GT a-Si EPID model to delivery errors for pre-treatment verification of IMRT fields [PDF]
A Monte Carlo model of an Elekta iViewGT amorphous silicon electronic portal imaging device (a-Si EPID) has been validated for pre-treatment verification of clinical IMRT treatment plans.
Hanlon, Peta +2 more
core
A review of electronic portal imaging devices (EPIDs) [PDF]
On‐line electronic portal imaging devices are beginning to come into clinical service in support of radiotherapy. A variety of technologies are being explored to provide real‐time or near real‐time images of patient anatomy within x‐ray fields during treatment on linear accelerators.
Boyer, Arthur L. +7 more
openaire +4 more sources
Epid Data Explorer (EDE) offers a browser-based interface for visual exploration and analysis of aggregated spatio-temporal ...
Chen, Fati +7 more
core +3 more sources
Objective: to estimate the frequency of prescription for antiosteoporotic agents in real clinical practice and treatment adherence within a year after experienced low-trauma osteoporotic fracture (LOF). Subjects and methods.
O. V. Dobrovolskaya +3 more
doaj +1 more source
Abstract Purpose/Objective We report our institutional clinical experience of treatment planning, dose evaluation, and delivery via the same‐day 3D MLC‐based crossfire method for spatially fractionated radiotherapy (SFRT) in conjunction with combination therapy. Additionally, we aimed to model our clinical outcome data to provide clinical insights into
Joshua Misa +3 more
wiley +1 more source
Schematic diagram of EPID-based 3D in vivo dose reconstruction.
Schematic diagram of EPID-based 3D in vivo dose reconstruction.
Yinghui Li (237776) +4 more
core +1 more source