Results 101 to 110 of about 8,615 (194)

2d dose measurement using a flat panel EPID

open access: yes, 2008
The increasing use of intensity modulated radiation therapy (IMRT) to deliver conformal radiation treatment has prompted the search for a faster and more cost effective quality assurance (QA) system.
Lim, Seng Boh
core   +1 more source

Investigation of an amorphous silicon EPID for measurement and quality assurance of enhanced dynamic wedge

open access: yes
This work assessed the dosimetric performance of an amorphous silicon electronic portal imaging device (EPID) for measurement and quality assurance of enhanced dynamic wedge (EDW) profile and wedge factor. EPID measurements of EDW profiles were corrected
Michael P. Barnes (21274832)   +1 more
core  

A comparison of a novel prototype electronic portal imaging device (EPID) with film and commercial epids

open access: yesInternational Journal of Radiation Oncology*Biology*Physics, 1998
Sanjiv S. Samant   +3 more
openaire   +1 more source

In vivo dosimetry using an electronic portal imaging device for pediatric myeloablative Total body irradiation with volumetric modulated arc therapy. [PDF]

open access: yesPhys Imaging Radiat Oncol
Greco F   +14 more
europepmc   +1 more source

In vivo δοσιμετρία ακτινοθεραπευτικής δέσμης φωτονίων με τη χρήση a-Si EPID

open access: yes, 2015
Σκοπός: Η αξιολόγηση μιας εύκολα εφαρμόσιμης μεθόδου δοσιμετρίας EPID, η οποία βασίζεται στη προσέγγιση της οπισθοπροβολής, και η σύγκρισή της με τη μέθοδο δοσιμετρίας EBT2 φιλμ. Μέθοδος: Προσδιορίστηκαν τα δοσιμετρικά χαρακτηριστικά του EPID.
Μανδουράρη Καλλιόπη
core  

A component-wise commissioning and validation framework for non-transit electronic portal imaging device patient-specific quality assurance. [PDF]

open access: yesPhys Imaging Radiat Oncol
Moghaddasi L   +7 more
europepmc   +1 more source

Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method

open access: yes, 2015
In vivo dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by ...
Yoon, JiHyung
core  

Direct dose to water dosimetry for pretreatment IMRT verification using a modified EPID

open access: yes, 2011
Purpose: Electronic portal imaging devices (EPIDs) are high resolution systems that produce electronic dose maps with minimal time required for equipment setup, and therefore potentially present a time-saving alternative for intensity modulated ...
Baldock, C (15601538)   +5 more
core  