An Analysis of Quality Assurance for Intensity-modulated Radiation Therapy and Volumetric Modulated Arc Therapy Treatment Plans Using Two Dosimetric Methods: The arcCHECK System and EPIbeam Based Dosimetric Approach [PDF]
Aim: The current study is to assess and compare the performance of an electronic portal imaging device (EPID)-based dosimetry system electronic portal imaging beam (EPIbeam) and a three-dimensional (3D) diode array system (ArcCHECK) using various gamma ...
Ajay Katake +4 more
doaj +2 more sources
Analysis of IMRT patient specific quality assurance using EPID measurement data from the Halcyon linear accelerator. [PDF]
This study investigated the characteristics of electronic portal imaging device (EPID)-based perpendicular field-by-field patient-specific quality assurance (PFF-PSQA) on the Halcyon linear accelerator by comparing them with the true composite (TC)-PSQA ...
Shinhaeng Cho +6 more
doaj +2 more sources
API-enabled integration of Pylinac with QATrack+ for automated EPID-based QA on Elekta linear accelerators: a technical note [PDF]
BACKGROUND: EPID quality assurance (QA) workflows remain largely manual and are difficult to standardise across treatment machines. This limits efficiency, increases operator dependency, and complicates consistent reporting and data sharing between ...
Oussama El Mouden +9 more
doaj +2 more sources
Evaluation of EPID-Based Transmission and DLG Correction Methods for Dosimetric Verification in HyperArc Single-Isocenter Multiple Target Radiosurgery [PDF]
Background/Objectives: Accurate verification of single-isocenter multiple-target (SIMT) stereotactic radiosurgery is challenging owing to the complexity of multi-lesion delivery and the sensitivity of stereotactic dose gradients. We aimed to evaluate the
Se An Oh +5 more
doaj +2 more sources
Improving patient treatment accuracy using transit dosimetry with Electronic Portal Imaging Device images and deep learning [PDF]
Background and Purpose:: Electronic portal imaging devices (EPID) can be utilized for transit in vivo dosimetry (IVD). A major limitation of standard amorphous Silicon EPID detectors for usage IVD is their non-linear detector response to water equivalent
Lorenzo Marini +9 more
doaj +2 more sources
Evaluation of Dose Distribution at the Level of Electronic Portal Imaging Device using Treatment Planning System [PDF]
Background: Treatment Planning Systems (TPS) are designed to calculate dose distributions within the CT imaging field of view. However, the Electronic Portal Imaging Device (EPID) is positioned outside this area, making it challenging to use standard TPS
Amene Bagheri +6 more
doaj +2 more sources
In-vivo dosimetry using electronic portal imaging in online-adaptive radiotherapy for rectal cancer [PDF]
Background and purpose: Electronic portal imaging device (EPID)-based in-vivo dosimetry (IVD) is widely used to verify radiotherapy dose delivery and detect deviations from anatomical changes, setup uncertainties, or machine-related errors. However, cone-
Gary Razinskas +7 more
doaj +2 more sources
Development of a new VMAT QA framework for Mobius3D using control-point specific EPID images [PDF]
PurposeThis study presents novel quality assurance (QA) approach for volumetric modulated arc therapy (VMAT) that leverages frame-by-frame electronic portal imaging device (EPID) images integrated into Mobius3D for accurate three-dimensional dose ...
JaeHyun Seok +13 more
doaj +2 more sources