COMP Report: Patient-specific quality assurance practices in Canadian radiotherapy-results from a national survey. [PDF]
Abstract Patient‐specific quality assurance (PSQA) is an essential component of modern radiotherapy, ensuring safe and accurate delivery of increasingly complex treatments. Given its resource‐intensive nature and the availability of evolving approaches, examining how PSQA is implemented and optimized across Canada is important to inform best practices.
Tran MN +7 more
europepmc +2 more sources
Sensitivity and concordance study of an open source EPID-based linear accelerator test suite. [PDF]
Abstract Background Electronic portal imaging devices (EPIDs) enhance linear accelerator (linac) quality assurance (QA) efficiency but are not universally used beyond patient‐specific IMRT QA. A multi‐institutional Consortium seeks to standardize linac QA utilizing an EPID‐based test suite.
Critchfield LC +14 more
europepmc +2 more sources
Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study [PDF]
Introduction: This research is a preliminary study of the development of Artificial Intelligence (AI) as a conversion tool from the pixel value of Cine a-Si 1000 Electronic Portal Imaging Device (EPID) images to dose.
Muhammad Ramadhan +2 more
doaj +1 more source
Quantitative evaluation of the effect of anatomical changes on the results of in vivo dosimetry during radiation therapy in the thoracic region. [PDF]
Abstract Background Anatomical changes during thoracic radiation therapy can alter dose delivery and compromise accuracy. Electronic portal imaging device (EPID)‐based in vivo dosimetry (IVD) enables noninvasive monitoring of these changes during treatment. Purpose This study quantitatively evaluated the impact of EPID‐based IVD in volumetric modulated
Tanaka K, Komori M.
europepmc +2 more sources
Development of an Electronic Portal Imaging Device Dosimetry Method
Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter ...
Jun Zhang +4 more
doaj +1 more source
Clinical Experience of Intensity Modulated Radiotherapy Pre-Treatment Quality Assurance for Carcinoma Head and Neck Patients with EPID and IMatriXX in Rural Center [PDF]
Background: Radiation therapy techniques as Intensity Modulated Radiotherapy (IMRT), rapid arc have been used for treatment of cancer with high accuracy.
M More, V Jain, O P Gurjar
doaj +1 more source
Resumen: Introducción: El objetivo del estudio fue conocer el manejo de los pacientes con enfermedad pulmonar intersticial difusa (EPID) asociada a enfermedades autoinmunes sistémicas (EAS) en las consultas de neumología especializadas en EPID en el ...
Orlando Acosta Fernández +5 more
doaj +1 more source
An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm [PDF]
Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study,
S M Hashemi +8 more
doaj +1 more source
Verification of IMRT and RapidArc Localized Prostate Cancer Treatment Plans Using EPID and Delta4 in vivo Dosimetry Methods [PDF]
Background: Quality assurance for intensity modulated radiation therapy (IMRT) depends on the type of dosimetry system and its evaluation procedure. We can check both the intensity and distribution of each field as the required pretreatment verification ...
Moustafa Ahmed +4 more
doaj +1 more source
Objectives: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT.
Yan-Hua Duan ME +12 more
doaj +1 more source