Results 201 to 210 of about 25,468 (231)
Some of the next articles are maybe not open access.

An efficient post-quantum secure dynamic EPID signature scheme using lattices

Multimedia tools and applications, 2023
C. Biswas, Ratna Dutta, Sumanta Sarkar
semanticscholar   +1 more source

Towards real-time EPID-based 3D in vivo dosimetry for IMRT with Deep Neural Networks: A feasibility study.

Physica medica (Testo stampato), 2023
J. Martins   +10 more
semanticscholar   +1 more source

EPID‐guided 3D dose verification of lung SBRT

Medical Physics, 2010
Purpose:To investigate the feasibility of utilizing tumor tracks from electronic portal imaging device (EPID) images taken during treatment to verify the delivered dose.Methods:The proposed method is based on a computation of the delivered fluence by utilizing the planned fluence and the tumor motion track for each field.
M, Aristophanous   +3 more
openaire   +2 more sources

Characterization of EPID software for VMAT transit dosimetry

Australasian Physical & Engineering Sciences in Medicine, 2018
Dosimetry check (DC) is a commercial software that allows reconstruction of 3D dose distributions using transit electronic portal imaging device (EPID) images. In this work, we evaluated the suitability of DC software for volumetric modulated arc therapy (VMAT) transit dosimetry.
Marco Esposito   +6 more
openaire   +2 more sources

Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

Strahlentherapie und Onkologie (Print), 2021
M. Esposito   +15 more
semanticscholar   +1 more source

Dose‐response characteristics of an amorphous silicon EPID

Medical Physics, 2005
Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac‐specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose‐response behavior. The aim of
Peter, Winkler   +2 more
openaire   +2 more sources

TU‐A‐BRA‐01: EPID, MVCT

Medical Physics, 2007
The Mega‐Voltage Cone‐Beam CT (MVCBCT) system provides a 3D image of the patient anatomy in the actual treatment position that can be tightly aligned to the planning CT, allowing daily verification and correction of the patient position moments before the dose delivery.
openaire   +1 more source

Dosimetric verification of IMRT and 3D conformal treatment delivery using EPID.

Applied Radiation and Isotopes, 2022
S. Nasseri   +6 more
semanticscholar   +1 more source

EPID-Based Dosimetry

2021
Brayden Schott   +3 more
openaire   +1 more source

Epid Dosimetry

AIP Conference Proceedings, 2011
Peter B. Greer   +5 more
openaire   +1 more source

Home - About - Disclaimer - Privacy