Results 21 to 30 of about 7,410 (208)
Verification of IMRT and RapidArc Localized Prostate Cancer Treatment Plans Using EPID and Delta4 in vivo Dosimetry Methods [PDF]
Background: Quality assurance for intensity modulated radiation therapy (IMRT) depends on the type of dosimetry system and its evaluation procedure. We can check both the intensity and distribution of each field as the required pretreatment verification ...
Moustafa Ahmed +4 more
doaj +1 more source
Breast in vivo dosimetry by EPID
An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two‐dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time.
Fidanzio, Andrea +9 more
+7 more sources
Objectives: This study performed dosimetry studies and secondary cancer risk assessments on using electronic portal imaging device (EPID) and cone beam computed tomography (CBCT) as image guided tools for the early lung cancer patients treated with SBRT.
Yan-Hua Duan ME +12 more
doaj +1 more source
wzbillings/EPID-8130-Final-Paper: Final paper draft
<p>This is the final draft of my paper for EPID 8130. Future updates will not edit the content of the paper unless absolutely necessary (or based on feedback after grading).</p> <p>In this work, I perform a systematic review of ...
Zane Billings
core +1 more source
Flexibility and efficiency in a radiotherapy department with different linear accelerators (linacs) can be improved if they are dosimetrically equivalent, and there is no need of plan or patient-specific quality assurance (PSQA) modification.
José Alejandro Rojas-López +1 more
doaj +1 more source
A Validation Method for EPID In Vivo Dosimetry Algorithms [PDF]
The aim of this study was to develop and apply an evaluation method for assessing the accuracy of a novel 3D EPID back-projection algorithm for in vivo dosimetry. The novel algorithm of Dosimetry Check (DC) 5.8 was evaluated. A slab phantom homogeneously filled, or with air and bone inserts, was used for fluence reconstruction of different squared ...
Marco Esposito +5 more
openaire +3 more sources
Background Exacerbations of chronic obstructive pulmonary disease (COPD) are an important measure of disease severity in terms of impaired disease progression, increased recovery time, healthcare resource utilization, overall morbidity and mortality.
Gunnar Johansson +6 more
doaj +1 more source
EPID‐based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams [PDF]
We proposed to perform a basic dosimetry commissioning on a new imager system, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter‐free (FFF) beams, then to develop an image‐based quality assurance (QA) model for verification of the system delivery accuracy for intensity‐
Miri, Narges +3 more
openaire +2 more sources
Aims: This study investigates the impact of cine acquisition mode on the dosimetric characteristics of a Varian aS500 amorphous silicon electronic portal imaging device (a-Si EPID).
Omemh Bawazeer +4 more
doaj +1 more source
Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices for Other applications for Linear Accelerator Quality Assurance [PDF]
Introduction: The success of radiation therapy depends critically on the accuracy of patient alignment in treatment position day after day. The primary use for Electronic portal imaging devices (EPIDs) is to monitor patient position during daily ...
Gena Mohamed +3 more
doaj +1 more source

