Results 201 to 210 of about 657,234 (310)
AAPM medical physics practice guideline 13.a: HDR brachytherapy, part B
Abstract The goal of this report is to assist the clinical medical physicist in assuring that key quality standards and practice considerations are met to ensure safe, reliable, and reproducible high dose rate (HDR) brachytherapy (BT) treatment. This guideline has been developed to provide appropriate minimum standards for such services.
Susan L. Richardson+8 more
wiley +1 more source
Equation of State of Classical Systems of Charged Particles
Stephen G. Brush+2 more
openalex +3 more sources
A NUMERICAL SOLUTION OF THE TWO DIMENSIONAL STEADY-STATE TURBULENT TRANSFER EQUATION [PDF]
Gour‐Tsyh Yeh, Wilfried Brutsaert
openalex +1 more source
Automated rapidplan model validation using Eclipse scripting API
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma+2 more
wiley +1 more source
Peng-Robinson or Redlich-Kwong? Twu or Soave α-Function? Which Combination of Cubic Equation of State (CEoS) and α-Function Produces More Accurate and Consistent Results for Pure Components. [PDF]
Mohamed T, Kozinski J, Ramos-Pallares F.
europepmc +1 more source
Long‐term stability analysis of beam shape in a robotic radiosurgery system
Abstract Purpose This study aimed to investigate the long‐term stability of CyberKnife beam profile parameters and assess their compliance with existing quality assurance (QA) guidelines. We evaluated beam profiles in both standard and diagonal planes over 3.5 years post‐installation to detect potential issues and ensure consistent beam quality.
Ryoichi Hinoto+4 more
wiley +1 more source
Equation of State of Four- and Five-Dimensional Hard-Hypersphere Mixtures. [PDF]
López de Haro M, Santos A, B Yuste S.
europepmc +1 more source
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley +1 more source