Results 251 to 260 of about 3,086,072 (317)
Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka+8 more
wiley +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki+9 more
wiley +1 more source
Abstract Purpose Studies on deep learning dose prediction increasingly focus on 3D models with multiple input channels and data augmentation, which increases the training time and thus also the environmental burden and hampers the ease of re‐training. Here we compare 2D and 3D U‐Net models with clinical accepted plans to evaluate the appropriateness of
Rosalie Klarenberg+2 more
wiley +1 more source
Commissioning evaluation of a deviceless 4DCT scanner
Abstract Background The utilization of four‐dimensional computed tomography (4DCT) for radiation therapy has not seen major advances to the method of data binning since shortly after inception. Recently there is increased interest in the utilization of an alternative binning method rather than more established techniques.
Hunter Tillery+2 more
wiley +1 more source
Abstract Background Acceleration treatment (AT) is a novel treatment planning parameter introduced in the tomotherapy‐dedicated treatment planning system, Precision. This study explores the effects of AT on tomotherapy plans using helical (TomoHelical) and direct (TomoDirect) irradiation techniques.
Ryosuke Shirata+9 more
wiley +1 more source
Dose rate correction of a diode array for universal wedge field dosimetric verification
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen+6 more
wiley +1 more source
Bone‐wise rigid registration of femur, tibia, and fibula for the tracking of temporal changes
Abstract Background Multiple myeloma (MM) induces temporal alterations in bone structure, such as osteolytic bone lesions, which are challenging to identify through manual image interpretation. The large variation in radiologists' assessments, even at expert centers, further complicates diagnosis.
Arttu Ruohola+5 more
wiley +1 more source
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner+4 more
wiley +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Journal of Metamorphic Geology, 2011
The thermodynamic properties of 254 end‐members, including 210 mineral end‐members, 18 silicate liquid end‐members and 26 aqueous fluid species are presented in a revised and updated internally consistent thermodynamic data set. The PVT properties of the
Roger Powell
exaly +2 more sources
The thermodynamic properties of 254 end‐members, including 210 mineral end‐members, 18 silicate liquid end‐members and 26 aqueous fluid species are presented in a revised and updated internally consistent thermodynamic data set. The PVT properties of the
Roger Powell
exaly +2 more sources