Results 171 to 180 of about 67,740 (222)

A Novel 9‐Channel 1H, 3‐Channel 31P Radiofrequency Coil for Interleaved Multinuclear Studies of Human Calf Muscle at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a double‐tuned calf coil with excellent 1H and 31P performance to study muscle physiology by interleaved 1H/31P MRS and parallel imaging at 7 T. Methods The coil combines three 1H transceive dipoles, six 1H receive‐only loops and three 31P transceive loops, arranged in a nested, half‐cylindrical layout.
Veronika Cap   +8 more
wiley   +1 more source

Motion‐ and Field‐Robust Mesoscopic Whole‐Brain T2*$$ {T}_2^{\ast } $$‐Weighted Imaging at 7 and 11.7 T Using Servo Navigation

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To mitigate artifacts related to motion and field changes in high‐resolution T2*$$ {T}_2^{\ast } $$‐weighted human brain imaging using servo navigation at ultra‐high fields up to 11.7 T. Methods MR‐based servo navigators were integrated into a segmented 3D‐EPI sequence to allow for prospective correction of involuntary head motion and ...
Matthias Serger   +15 more
wiley   +1 more source

Strong‐Gradient Diffusion‐Weighted Imaging of Prostate Cancer Using an Inside‐Out Nonlinear Gradient Coil

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To demonstrate improved image quality and lesion conspicuity in prostate diffusion‐weighted imaging (DWI) using an inside‐out nonlinear gradient coil that provides locally strong gradients (200–500 500 mT/m) at typical prostate positions.
Horace Z. Zhang   +8 more
wiley   +1 more source

T2$$ {\boldsymbol{T}}_{\mathbf{2}} $$‐Weighted Imaging of Water, Fat and Silicone

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Magnetic resonance imaging (MRI) is a sensitive method for assessing silicone implant integrity, with T2$$ {\boldsymbol{T}}_{\mathbf{2}} $$‐weighted imaging being essential for detecting abnormalities in surrounding tissue. Silicone breast imaging protocols often require multiple tailored sequences for species suppression and ...
Aizada Nurdinova   +6 more
wiley   +1 more source

Field Strength‐Dependent White Matter R1 and R2 Anisotropy of Phase‐Cycled Balanced Steady‐State Free Precession Relaxometry

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To investigate how the relaxation rates (R1, R2) and asymmetry indices (AI), derived from phase‐cycled balanced steady‐state free precession (pc‐bSSFP) data, depend on the orientation of white matter (WM) fiber tracts at different field strengths.
Florian Birk   +8 more
wiley   +1 more source

Analytical Dual Flip Angle R1 Calculation Outside the Small-Angle Regime. [PDF]

open access: yesMagn Reson Med
Edwards LJ   +6 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy