Results 41 to 50 of about 367,675 (210)
Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of ...
Chance M. Witt +15 more
doaj +1 more source
Temperature sensors, such as Fiber Bragg Grating (FBG) and thermocouple (TC), have been widely used for monitoring the interstitial tissue temperature during laser irradiation.
Minh Duc Ta +4 more
doaj +1 more source
Background: The safety and efficacy of radiofrequency hot balloon catheter (Toray-Satake balloon [TSB]) ablation for the treatment of atrial fibrillation (AF) was evaluated in a 3-center pilot study.
Hiroshi Sohara, MD +8 more
doaj +1 more source
OBJECTIVES:. Acute respiratory distress syndrome is treated by utilizing a lung protective ventilation strategy. Obesity presents with additional physiologic considerations, and optimizing ventilator settings may be limited with traditional means ...
Jesse Liou, MD +8 more
doaj +1 more source
Esophageal balloon calibration during Sigh: A physiologic, randomized, cross-over study
PURPOSE: Optimal esophageal balloon filling volume (Vbest) depends on the intrathoracic pressure. During Sigh breath delivered by the ventilator machine, esophageal balloon is surrounded by elevated intrathoracic pressure that might require higher ...
Pesenti, Antonio +50 more
core +2 more sources
Removal of Rare Esophageal Impacted foreign Bodies Using an Endoscopic Esophageal Balloon Catheter with an Attached PTCA Inflation Device [PDF]
application/pdfJournal ArticleWe herein report two very rare cases of esophageal foreign bodies that were removed using an\nendoscopic esophageal balloon dilation catheter with an attached percutaneous transluminal coronary\nangioplasty(PTCA)inflation ...
18201 +15 more
core
Esophageal dilation with integrated balloon imaging: initial evaluation in a porcine model
Background: When treating achalasia, balloon dilation is often combined with fluoroscopy to allow the lower esophageal sphincter to be visualized as it is being dilated.
John O’Dea, Peter D. Siersema
doaj +1 more source
Catheter ablation of atrial fibrillation : radiofrequency catheter ablation for redo procedures after cryoablation [PDF]
Aim: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation. Methods: Thirty patients (paroxysmal atrial fibrillation: 22 patients, persistent atrial
Gramley, Felix, Kettering, Klaus
core +1 more source
How to achieve balloon stability in aortic valvuloplasty using rapid ventricular pacing [PDF]
Balloon aortic valvuloplasty is now the treatment of choice for congenital aortic stenosis. Balloon stability may be difficult to achieve and this may result in a suboptimal result or even valve damage.
Shebani, S. +3 more
core
Graphical Abstract ABSTRACT Fluoroscopy has traditionally been the mainstay imaging technique for guidance during electrophysiology (EP) ablation procedures. The numerous disadvantages associated with radiation exposure for both operators and patients have created the need for zero‐fluoroscopy (ZF) approaches. Today, electrophysiologists have access to
Dimitrios Kotzadamis +6 more
wiley +1 more source

