Results 211 to 220 of about 28,061 (312)

A systematic review on patient perceptions and clinician‐reported outcomes when comparing digital and analog workflows for complete dentures

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To compare digitally fabricated complete dentures to conventionally fabricated dentures using patient‐ and clinician‐reported outcome measures. Methods This review was structured according to PRISMA guidelines with the protocol registered in the PROSPERO database (CRD42024526069).
Amira Fouda   +4 more
wiley   +1 more source

The effects of anodization and instrumentation on titanium abutment surface characteristics and biofilm formation

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To assess the impact of anodization and instrumentation on titanium abutment surface characteristics (surface roughness and wettability) and biofilm formation (viability and mass). Materials and Methods Titanium discs were obtained from pre‐milled abutment blanks made of titanium‐6aluminum‐7niobium alloy.
Weiqing Liu   +4 more
wiley   +1 more source

Peri‐implant tissue definition and registration with a 3D‐printed emergence profile former on titanium stock healing abutment: A dental technique and clinical report

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Recent focus has shifted toward refining the soft tissue emergence profile to enhance aesthetics, support peri‐implant health, and ensure long‐term success. Traditionally, titanium stock healing abutments or chairside‐customized abutments were used to shape peri‐implant tissues and develop the emergence profile for implant‐supported prostheses.
Francisco X. Azpiazu‐Flores   +5 more
wiley   +1 more source

Marginal gap of printed, milled, and heat‐pressed two‐piece polyetheretherketone abutments before and after thermal cycling, and their pull‐off bond strength after thermal cycling

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the marginal gap of two‐piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull‐off bond strength. Materials and Methods A two‐piece abutment was virtually designed after digitizing a titanium‐base (Ti‐base) abutment.
Almira Ada Diken Türksayar   +6 more
wiley   +1 more source

Assessment of impact of a control die on marginal fidelity of milled zirconia crown copings for finishing and polishing

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose This study evaluated and compared the marginal fidelity of milled zirconia copings before and after finishing and polishing with and without a control die. Materials and Methods This prospective multicenter in vitro trial involved two methods regularly used in two clinics for hybrid and full‐digital workflows.
Marwan Al Akkad   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy