Results 121 to 130 of about 1,682 (149)
Etalonnage d'une station hydrologique difficile : le Banian, station principale du Mangoky
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Canadian Journal of Physics, 1976
A procedure for the calibration of the sextant is given in which the only instruments required are: two autocollimators, a plane mirror, and a surface plate of good quality.
Gratien Bouillon +2 more
openaire +1 more source
A procedure for the calibration of the sextant is given in which the only instruments required are: two autocollimators, a plane mirror, and a surface plate of good quality.
Gratien Bouillon +2 more
openaire +1 more source
Etalonnage absolu d’un spectrometre SISAM
Applied Optics, 1970A SISAM spectrometer was adjusted. It was fitted with an apparatus for measuring absolute wavelengths. This used the fringes of a Fabry-Perot with emission lines. The results indicate that the width of the apparatus function is less than 0.025 cm(-1) and that the relative accuracy of the wavelength measurements is 0.003 cm(-1).
R, Farrenq +4 more
openaire +2 more sources
Etalonnage de l’analyse spectrale par la méthode du modèle autorégressif
Annales des Télécommunications, 1981Dans l’etude de la densite spectrale de puissance d’un bruit blanc additionne a un signal a frequence pure par la methode du modele autoregressif, les auteurs etablissent une formule generale permettant d’etalonner cette methode d’analyse en fonction de l’ordre du filtre autoregressif et du rapport signal sur bruit d’entree.
Lacoume, Jean-Louis +2 more
openaire +2 more sources
Etalonnage de polygones optiques par interférométrie en lumière laser
Canadian Journal of Physics, 1970It is current practice to use autocollimators to calibrate optical polygons. An interferometric method in laser light is described.
Gratien Bouillon +2 more
openaire +1 more source
Etalonnage de cales étalons angulaires par la méthode de zéro
Canadian Journal of Physics, 1981A method used to calibrate a set of reference angle gage blocks is described. Only the equipment usually found in a dimensional metrology laboratory is used, such as autocollimators and a surface plate. Contrary to some other well-known methods, supplementary sets of angle gage blocks, a high precision dividing head or a rotary table are not needed ...
Gratien Bouillon +2 more
openaire +1 more source
Etalonnage des sondes parietales a film chaud en regime permanent
International Communications in Heat and Mass Transfer, 1985Abstract The utilization of hot film probes for the measurement of wall shear stress requires the realization of a calibration channel which permits to study the probes responses, to draw the calibration curves in laminar and turbulent flows and to propose the laws in the following form: Nu = K τ p ∗ n .
M Saighi, A Degiovanni, M Martin
openaire +1 more source
Etalonnage à deux points dans un système d'immunodosage
Immuno-analyse & Biologie Spécialisée, 1990Ciba Corning Diagnostics a d~velopp~ un calcul d'ajustement de courbe & 2 points, adapt~ au syst~me d'lmmunodosage Magic Lite [1]. Cet ajustement s'effectue gr&ce & une courbe maitresse de calibration d~finie Iors de la fabrication du lot et & 2 points d'~talonnage inclus dans chaque s~rie de dosages.
openaire +1 more source
The International Journal of Applied Radiation and Isotopes, 1973
Resume Les auters decrivent une methode d'incorporation directe pour comptage en scintillation liquide d'echantillons plasmatiques. Apres dilution dans une solution isotonique de chlorure de sodium, les echantillons sont incorpores dans un nouveau melange scintillant-emulsionnant (“Scintigel”).
C. Bader +3 more
openaire +1 more source
Resume Les auters decrivent une methode d'incorporation directe pour comptage en scintillation liquide d'echantillons plasmatiques. Apres dilution dans une solution isotonique de chlorure de sodium, les echantillons sont incorpores dans un nouveau melange scintillant-emulsionnant (“Scintigel”).
C. Bader +3 more
openaire +1 more source

