Results 201 to 210 of about 2,755,352 (247)

The effect of multi‐leaf collimator leaf width on VMAT treatment plan quality

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The advent of volumetric modulated arc therapy (VMAT) in radiotherapy has made it one of the most commonly used techniques in clinical practice. VMAT is the delivery of intensity modulated radiation therapy (IMRT) while the gantry is in motion, and existing literature has shown it has decreased treatment delivery times and the ...
Gregory Sadharanu Peiris   +3 more
wiley   +1 more source

The effect of kV imaging dose on PTV and OAR planning constraints in lung SBRT using stereoscopic/monoscopic real‐time tumor‐monitoring system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real‐time tumor monitoring. Materials and Methods Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the ...
Ruwan Abeywardhana, Mike Sattarivand
wiley   +1 more source

Evaluation of the dose reduction effect of crystalline lens exposure in cone‐beam computed tomography with bismuth eye shield for image‐guided radiation therapy: An anthropomorphic phantom study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida   +5 more
wiley   +1 more source

Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR‐only radiotherapy planning in brain tumors?

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui   +3 more
wiley   +1 more source

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

A review of artificial intelligence in brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen   +4 more
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

Why dignity is a troubling concept for AI ethics. [PDF]

open access: yesPatterns (N Y)
Rueda J   +12 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy