Results 41 to 50 of about 26,382 (159)

No difference in bacterial contamination of hip capsule sutures and control sutures in hip arthroplasty surgery

open access: yes, 2023
Background Perioperative preventive measures are important to further reduce the rate of periprosthetic joint infections (PJI) in patients undergoing total hip arthroplasty (THA).
Jon H. M. Goosen   +5 more
core   +1 more source

Dual‐Scaffold Technique: Autologous Minced Cartilage and Bone Marrow Aspirate Scaffold Combined With Synthetic Collagen Membrane for Cartilage Repair

open access: yesArthroscopy Techniques, Volume 15, Issue 9, September 2026.
Abstract Treating cartilage injuries has long been a complex challenge; however, recent progress has greatly increased the variety of effective therapeutic approaches. The minced autologous matrix‐induced chondrogenesis plus procedure for full‐thickness knee cartilage lesions uses a collagen matrix combined with shaver‐minced cartilage graft and bone ...
Leonardo Ataíde   +5 more
wiley   +1 more source

Self-Propelled Soft Everting Toroidal Robot for Navigation and Climbing in Confined Spaces [PDF]

open access: yes, 2022
There are many spaces inaccessible to humans where robots could help deliver sensors and equipment. Many of these spaces contain three-dimensional passageways and uneven terrain that pose challenges for robot design and control. Everting toroidal robots,
Perez, Nelson G. Badillo   +1 more
core   +1 more source

Arthroscopic Repair of Labrum Using the Inverted V‐Shape Double‐Strand Vertical Mattress Suture Technique in Hip Joint

open access: yesArthroscopy Techniques, Volume 15, Issue 9, September 2026.
Abstract The labral suture is essential in the arthroscopic treatment of hip acetabular labral injuries and maintains its suction sealing effect. The traditional single‐strand loop fixation, with its loop around the labrum tissue, may cause labral eversion and disrupt the sealing effect.
Yang He   +5 more
wiley   +1 more source

Arthroscopic All‐Inside/All‐Suture Repair of Complete Radial Tear of the Lateral Meniscus Using a Percutaneous Single‐Needle Technique

open access: yesArthroscopy Techniques, Volume 15, Issue 9, September 2026.
Abstract Radial tears of the lateral meniscus have limited healing potential and unfavorable biomechanics, and current suture constructs that use capsular rip‐stop stitches may increase meniscal extrusion and constrain native motion. This technical note describes an all‐inside, crossed, meniscus‐based repair for complete or near‐complete radial tears ...
Diego Sánchez Cruz   +3 more
wiley   +1 more source

Efficacy of lid everting suture in the management of involutional lower eyelid entropion using 4-0 silk versus 4-0 chromic catgut

open access: yes, 1970
Background: Involutional lower eyelid entropion is a common ophthalmic condition requiring surgical correction. Objective: To compare the efficacy of lid everting sutures in the management of involutional lower lid entropion using 4-0 silk versus 4-0 ...
SK Singh, H Das, P Lavaju
core   +1 more source

Modified Das De Procedure in Peroneus Longus Tendon Dislocation: Technical Note

open access: yesArthroscopy Techniques, Volume 15, Issue 9, September 2026.
Abstract Peroneal tendon dislocation is an uncommon ankle injury that may be misinterpreted as a lateral ankle sprain due to similar clinical characteristics. It frequently leads to delayed treatment and recurrent instability. Although various surgical approaches have been described, including osseous procedures such as groove deepening and soft‐tissue
I. Wayan Subawa, Febyan Febyan
wiley   +1 more source

Application of laparoscopic backtracking full-thickness continuous everting suture for non-AOSC choledocholithiasis

open access: yes, 2023
Background Based on the current trend of increasing incidence of choledocholithiasis, it is of great significance to explore the closure method of the common bile duct during laparoscopic choledocholithotomy.
Chenchen Kong   +4 more
core   +1 more source

Lateral Meniscus Oblique Radial Tear All‐Inside Repair

open access: yesArthroscopy Techniques, Volume 15, Issue 9, September 2026.
Abstract Lateral meniscus oblique radial tears, particularly high‐grade types 3 and 4, are common in acute anterior cruciate ligament injuries and contribute to significant knee instability and meniscal extrusion if left unrepaired. Surgical repair is necessary to restore normal knee kinematics and meniscal function.
Patrick M. Ryan   +4 more
wiley   +1 more source

Murine Model of Venous Bypass Grafting to Study Determinants of Graft Patency

open access: yesCurrent Protocols, Volume 6, Issue 9, September 2026.
Abstract The investigation of patency and remodeling in venous grafts requires a reproducible animal model that enables the study of the underlying cellular and molecular processes. Here, we describe a simplified mouse model for venous bypass grafts, in which the inferior thoracic vena cava (IVC) of a donor mouse is interposed into the common carotid ...
Vanessa Heim   +17 more
wiley   +1 more source

Home - About - Disclaimer - Privacy