Results 151 to 160 of about 89,593 (382)
Summary This second part of the S3 guideline on the diagnosis and treatment of alopecia areata (AA), presents key recommendations on topical and systemic therapy, quality of life and support services. The first part of the guideline, published separately, covers the definition and content of epidemiology and diagnosis as well as comorbidities, risk and
Ulrike Blume‐Peytavi +13 more
wiley +1 more source
Objective: To conduct a systematic review of the literature evaluating the efficacy of the 308 nm excimer lamp in comparison to narrowband ultraviolet B (NB-UVB) and the 308 nm excimer laser for inducing repigmentation in vitiligo.
Nathalia Bakes Teodoro +4 more
doaj +1 more source
Microhollow Cathode Discharge Excimer Lamps
Microhollow cathode discharges are high-pressure, nonequilibrium gas discharges between a hollow cathode and a planar or hollow anode with electrode dimensions in the 100 μm range. The large concentration of high-energy electrons, in combination with the
Karl H. Schoenbach +9 more
core +1 more source
Key Points Low‐Mg calcite RM developed for in situ microanalysis applications in palaeoclimatology (δ18O, δ13C; Mg, Sr m/m). New data for calcite CRM IAEA‐603 (δ18O, δ13C by SIMS and GS‐IRMS; Mg m/m). No detectable IMF effect of Mg on SIMS δ18O determinations for mass fractions < 3650 μg g‐1.
Andreas T. Hertwig +13 more
wiley +1 more source
Key Points Measurement of 86Sr at count rates < 1500 cps can result in statistical bias. Non‐linear signals in analogue detection mode (e.g., Rb) present a challenge for accurately dating high 87Rb/86Sr mica (> 1000). Accounting for these considerations, high 87Rb/86Sr mica are dated here with accuracies of ∼ 1%.
Duane C. Petts +5 more
wiley +1 more source
Electrohydrodynamic excimer laser: Ultra-compact system and laser energy performance dynamics
Excimer lasers, essential deep ultraviolet gas light sources, have consistently encountered significant challenges in achieving miniaturization while maintaining high performance. These challenges have limited their broader application and development in
Jin-Liang Han +6 more
doaj +1 more source
Heavy ion beam pumped KrF* excimer laser
The high energy loss of heavy ions in matter as well as the small angular scattering makes heavy ion beams an excellent tool to produce almost cylindrical and homogeneously excited volumes in matter.
Adonin, Aleksey
core
Key Points 7 μm spot‐diameter LA‐MC‐ICP‐MS analyses yield accurate zircon U‐Pb ages. 1013 Ω amplifier resistors improve low‐signal Pb measurements. Saturn correction protocols minimise down‐hole fractionation effects. We present a systematic evaluation of high spatial‐resolution zircon U‐Pb dating using a Thermo Scientific Neoma multi‐collector ICP‐MS ...
Cristiano Lana, John D. Clemens
wiley +1 more source

