Results 81 to 90 of about 27,766 (222)
A 4E comparison of PEMFC‐ORC and DMFC‐ORC systems shows that PEMFC‐ORC achieves 21% higher energy efficiency, while DMFC‐ORC obtains 31% higher exergy efficiency and 57% lower levelized cost of electricity. However, DMFC‐ORC emits nearly twice the annual carbon dioxide equivalent of PEMFC‐ORC.
Zahra Piryaei +2 more
wiley +1 more source
Coordination of exergy analysis and the MIND method - applied to a pulp and board mill
The MIND (Method for analysis of INDustrial energy systems) method has been developed for cost optimisation of industrial energy systems, mainly with regard to quantities of energy.
Gong, Mei,, Karlsson, Magnus,
core +1 more source
Exergy analysis and optimisation of a hybrid solar-geothermal power plant
The present study aims at the energy, exergetic, exergoeconomic, exergoenvironmental analysis of a hybrid solar-geothermal power plant. In addition, the emergy-based approach based on exergoeconomic and exergoenvironmental analysis has been performed ...
Ana M. Blanco Marigorta +5 more
core +1 more source
Exergy Analysis of a Bio-System: Soil–Plant Interaction
This paper explains a thorough exergy analysis of the most important reactions in soil–plant interactions. Soil, which is a prime mover of gases, metals, structural crystals, and electrolytes, constantly resembles an electric field of charge and ...
Masoomeh Bararzadeh Ledari +3 more
doaj +1 more source
A novel combined cooling and power generation system is proposed by integrating organic Rankine cycle (ORC) with an absorption heat transformer, which is driven by combining geothermal energy and data center's waste heat. The system using R601a yielded the best overall performance, achieving an exergy efficiency of 40.34% and an annual cost of 130.29 k$
Zerui Chen +4 more
wiley +1 more source
Influence of Structural and Environmental Parameters on Solar Air Collector Performance
Increasing air gap depth and mass flow rate significantly enhances the thermal performance of solar air collectors, with optimal performance achieved at an 8.5 cm air gap and 0.01318 kg/s mass flow rate. Air gap depth is identified as the dominant factor influencing system efficiency.
Quankun Zhu +2 more
wiley +1 more source
In this study, exergy (availability) analysis of a Spark Ignition (SI) engine has been performed theoretically during compression, combustion and expansion processes of the engine cycle.
Bilgin, Atilla, Sezer, İsmet
core +1 more source
ABSTRACT Green hydrogen produced through renewable energy‐powered water electrolysis is a promising pathway for decarbonizing future energy systems. However, the performance, economic feasibility, and environmental implications of integrated photovoltaic (PV) hydrogen systems under tropical climatic conditions remain insufficiently explored. This study
Abdelhak Lekbir +5 more
wiley +1 more source
Fixed‐bed reactor experiments (10 L) validate the iron–steam redox process, bridging material‐scale research and industrial power‐to‐power applications. Coupled with SOEC/SOFC systems, this framework defines critical interfaces for heat and gas management. Results confirm reproducible hydrogen storage and release, demonstrating technical feasibility at
Julien Göthel +2 more
wiley +1 more source
In-Depth Exergy Analysis of the Thermochemical Conversion of Flax Straw via Pyrolysis
Pyrolysis is a promising thermochemical conversion process for transforming biomass waste into valuable products like bio-oil, syngas, and biochar. Understanding the thermodynamic efficiency of this process is important for optimizing its design and ...
Aknur Temireyeva +2 more
doaj +1 more source

