Results 281 to 290 of about 12,556,675 (343)
Some of the next articles are maybe not open access.

Radon exhalation rate prediction and early warning model based on VMD-GRU and similar day analysis.

Journal of Environmental Radioactivity
To improve the safety and reliability of radon exhalation rate monitoring systems, this study introduces an early warning method that integrates a VMD-GRU prediction model with a similar day analysis.
Shijie Fang   +4 more
semanticscholar   +1 more source

The results of long-term simultaneous measurements of radon exhalation rate, radon concentrations in soil gas and groundwater in the fault zone.

Applied Radiation and Isotopes, 2020
The regular monthly radon measurements were carried out in the fault zone on the Western slope of the Beshtau magmatic massif (North Caucasus). The radon exhalation rate from the soil surface, as well as radon concentrations in soil gas at a depth of 0.5 
P. Miklyaev   +7 more
semanticscholar   +1 more source

Building materials radon exhalation rate: ERRICCA intercomparison exercise results

Science of The Total Environment, 2001
The Nuclear Engineering Section of the National Technical University of Athens undertook the organisation of a European building material radon exhalation rate intercomparison exercise in the framework of the European Research into Radon In Construction Concerted Action (ERRICCA).
N P, Petropoulos   +2 more
openaire   +2 more sources

Building material radon emanation and exhalation rate: Need of a shared measurement protocol from the european database analysis.

Journal of Environmental Radioactivity, 2020
In this paper the authors present a collection of radon emanation and exhalation rate data of about 2000 samples of building materials used in Europe. The data analysis highlighted some critical issues, such as the use of different units to express radon
C. Nuccetelli, F. Leonardi, R. Trevisi
semanticscholar   +1 more source

Novel approaches for accurately measuring radon exhalation rate and mechanism interpreted by numerical simulation.

Journal of Hazardous Materials
Measurements of radon exhalation rate using traditional methods can be affected by back-diffusion or differential pressure in the accumulation chamber, resulting in deviations between the measured and the true values.
Ming Xia, Yongjun Ye, Ning Zhou
semanticscholar   +1 more source

Relation Between Limiting Exhalation Flow Rate and Lung Volume

IEEE Transactions on Biomedical Engineering, 1987
A previous communication presented a procedure to convert perturbational airways resistance to plethysmographic resistance. While working with this procedure, we discovered that one of the unknown exhalation parameters must be, set to a value of 1.0, and another represents the inverse of the respiratory system time constant.
A T, Johnson, J M, Milano
openaire   +2 more sources

Evaluation of accurate measurement methods for radon exhalation rate with advection effect and application in field.

Journal of Hazardous Materials
In decommissioning of a uranium tailings pond, radon exhalation rates on a beach surface should meet regulatory standards. Accurate measurements of the radon exhalation rate are demanded.
Ming Xia, Yongjun Ye
semanticscholar   +1 more source

Study on a new charcoal closed chamber method for measuring radon exhalation rate of building materials

Radiation Measurements, 2020
To develop an accurate and convenient measurement method for radon exhalation rate of building materials is of great importance not only for mitigation of indoor radon, but also for public health.
Song Yanchao   +4 more
semanticscholar   +1 more source

Compressive strength, water absorption, water sorptivity and surface radon exhalation rate of silica fume and fly ash based mortar

Journal of Building Engineering, 2019
In this study, the effect of partial cement replacement with silica fume and fly ash on the compressive strength, water absorption, volume of permeable pore, water sorptivity, radon content and surface radon exhalation rate of mortar mixtures were ...
Daniel Hatungimana   +4 more
semanticscholar   +1 more source

Radon and Thoron exhalation rate map in Japan

AIP Conference Proceedings, 2008
Measurements of radon and thoron exhalation rates have been done using the radon and thoron exhalation rate measuring instrument adopting the accumulation method. We obtained the 111 data in the 40 sites of the 14 prefectures in Japan. The arithmetic average value of the radon and thoron exhalation rates by all 111 data were obtained to be 8.6 mBq⋅m−2 ...
Hosoda Masahiro   +8 more
openaire   +1 more source

Home - About - Disclaimer - Privacy