Results 21 to 30 of about 18,852 (226)
Objective:In this study, 14-month clinical outcomes of the endoprosthesis and pertrochanteric external fixator application are retrospectively evaluated in elderly patients with pertrochanteric fractures. Patients and Method: A total of 45 patients of
Aydin Ekrem, Ates Ali
doaj +1 more source
This paper presents a comparative analysis of the biomechanical characteristics of an external fixator with a frame made of two different materials (stainless steel and composite material) during anterior–posterior bending.
Nedim Pervan +4 more
doaj +1 more source
Growth Plate Injuries of the Lower Extremity: Case Examples and Lessons Learned. [PDF]
BackgroundThe presence of growth plates at the ends of long bones makes fracture management in children unique in terms of the potential risk of developing angular deformities and growth arrest.Materials and methodsWe discuss three distinct cases ...
Sabharwal, Samir, Sabharwal, Sanjeev
core +3 more sources
Medium-Long-Term Radiographic and Clinical Outcomes after Surgical Treatment of Intra-Articular Tibial Pilon Fractures by Three Different Techniques [PDF]
The goal of this retrospective, observational, case series study was to evaluate the medium-long-term clinical and radiographic results of the three most common surgical osteosynthesis techniques used for the treatment of articular tibial pilon fractures:
Angelini, Andrea +7 more
core +3 more sources
Treatment of neglected elbow dislocations with the help of hinged external fixator: Report of two cases [PDF]
Elbow dislocations are cases that have to be treated in emergency conditions. Neglected elbow dislocations are seen very rarely and the treatment of such cases are more complicated than acute cases.
Mehmet Fatih Erol +2 more
core +1 more source
Design and biomechanical study of slide-poking external fixator for hip fracture
Background Femoral head collapse and coxa vara lead to internal fixator failure in elderly patients with hip fracture. External fixator application is an optimal choice; however, the existing methods have many disadvantages.
Hua-Biao Chen +3 more
doaj +1 more source
In vivo measurement of bending stiffness in fracture healing [PDF]
Background Measurement of the bending stiffness a healing fracture represents a valid variable in the assessment of fracture healing. However, currently available methods typically have high measurement errors, even for mild pin loosening.
RR Hammer +33 more
core +1 more source
The nonunion of distal phalangeal communized fracture is relatively rare in hand fractures. However, if it occurred, the surgical treatment is quite difficult because of small piece of fragmentations.
Satoshi Ichihara +4 more
doaj +1 more source
Introduction: The application of an external fixator for unstable pelvic fractures is an important component of many resuscitation protocols. Moreover, certain pelvic fractures may be treated with an external fixator without requiring further internal ...
Matthias K. Russ +7 more
doaj +1 more source
Rigidity of unilateral external fixators - A biomechanical study [PDF]
Introduction: External fixation is the primary choice of temporary fracture stabilisation for specific polytrauma patients. Adequate initial fracture healing requires sufficient stability at the fracture site. The purpose of this study was to compare the
Burgers, P.T.P.W. (Paul) +5 more
core +2 more sources

