Digital guides in eye care: Comparing AI model accuracy and reliability. [PDF]
Savaş HV, Altay O.
europepmc +1 more source
ABSTRACT Accurately knowing the frontier orbital energies of the structurally disordered small‐molecule organic semiconductors that are used in optoelectronic devices such as organic light‐emitting diodes is required to rationally improve their performance. Here, we show that these energies can be deduced with a large accuracy from the peak energies of
Christian B. McDonald +7 more
wiley +1 more source
Enhancing access and clinical triage in primary eye care through digital vision testing: validation of the SightConnect mobile application. [PDF]
Sangani P +10 more
europepmc +1 more source
This study presents a compact dynamic‐field‐driven nucleation and growth (DFNG) model that captures ferroelectric switching behavior under arbitrary voltage waveforms. It enables extraction of time‐dependent domain wall velocity and growth dimensionality, which can then be extended to device‐level modeling.
Yi Liang +10 more
wiley +1 more source
The Israeli eye care system through a public and global health lens. [PDF]
Arazi M +4 more
europepmc +1 more source
Near‐Unity Chiral Lasing Enabled by Quasi‐Bound States in the Continuum
Nanoimprinted chiral array that supports bound states in the continuum is doped with an efficient non‐chiral molecule (Rhodamine‐B) acting as gain medium to produce fully circularly polarized lasing emission. The chiral lasing wavelength can be tuned across the emission band of Rhodamine‐B by adjusting the coating thickness of the TiO2 high refractive ...
Jose Mendoza‐Carreño +5 more
wiley +1 more source
A Cross-Sectional Study on the Prevalence and Risk Factors of Steroid-Induced Glaucoma at a Tertiary Eye Care Hospital. [PDF]
Vks K +4 more
europepmc +1 more source
Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management
A soft contact lens sensor enables continuous, noninvasive monitoring of nocturnal intraocular pressure (IOP) under closed‐eye sleep conditions. By integrating a highly compliant inductive–capacitive circuit onto a commercial lens, the device achieves record sensitivity and stable performance.
Yumin Dai +19 more
wiley +1 more source
Distribution and Patterns of Refractive Errors in a Pediatric Amblyopic Cohort Aged 3-5 Years: A Descriptive Study in a Pakistani Tertiary Eye Care Center. [PDF]
Bukhari SF +5 more
europepmc +1 more source
We report a wearable photonic patch integrating room light‐ and sunlight‐activatable luminescent particles (RSLPs) for both photochemical tissue bonding and photobiomodulation. RSLPs harvest ambient light and emit red luminescence to drive chlorin e6–mediated collagen crosslinking.
Kyungjoo Jo +12 more
wiley +1 more source

