Two-dimensional ultrasound receive array using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging [PDF]
A 2-D optical ultrasound receive array has been investigated. The transduction mechanism is based upon the detection of acoustically induced changes in the optical thickness of a thin polymer film acting as a Fabry-Perot sensing interferometer (FPI).
Beard, P.C.
core
Thermospheric winds and temperatures above Mawson, Antarctica, observed with an all-sky imaging, Fabry-Perot spectrometer [PDF]
A new all-sky imaging Fabry-Perot spectrometer has been installed at Mawson station (67°36' S, 62°52' E), Antarctica. This instrument is capable of recording independent spectra from many tens of locations across the sky simultaneously.
Anderson, C. +9 more
core +2 more sources
WAMDII: wide-angle Michelson Doppler imaging interferometer for Spacelab [PDF]
A wide-angle Michelson Doppler imaging interferometer (WAMDII) is described that is intended to measure upper atmospheric winds and temperatures from naturally occurring visible region emissions, using Spacelab as a platform.
Gault, W.A. +8 more
core +1 more source
This report presents an 8‐inch quasi‐standard piezoelectric integrated MEMS technology (PIMT) platform which, through the integration of core and additional processes, reliably supports three rounds of multi‐project wafer (MPW) fabrication. Whilst ensuring support for mass production processes, the platform offers certain flexibility, providing a ...
Yongquan Su +18 more
wiley +1 more source
ZEMAX Simulations and Experimental Validation of Laser Interferometers
This study presents the design, simulation, and experimental validation of six fundamental laser interferometer types: Sagnac, Mach–Zehnder, Michelson, Twyman–Green, Fizeau, and Fabry–Pérot.
Muddasir Naeem, Tayyab Imran
doaj +1 more source
Interferometric Fiber Optic Sensors
Fiber optic interferometers to sense various physical parameters including temperature, strain, pressure, and refractive index have been widely investigated. They can be categorized into four types: Fabry-Perot, Mach-Zehnder, Michelson, and Sagnac.
Hae Young Choi +6 more
doaj +1 more source
From Flexible to Conformable Pressure Sensors: Mechanisms, Materials, and Biomedical Applications
This review highlights recent progress, challenges and future opportunities in pressure sensing for advanced biomedical applications. We summarize key transduction mechanisms and emerging material strategies, discuss representative wearable and implantable applications for continuous physiological monitoring and provide a focused perspective on barrier
Rishabh B. Mishra +2 more
wiley +1 more source
The Gamma Factory: A New Experimental Paradigm for the Post‐HL‐LHC Era
ABSTRACT The Gamma Factory (GF) proposal is motivated by the recognition of a largely untapped potential of the CERN accelerator complex to enable a new research program at the intersection of particle, nuclear, atomic, fundamental, and applied physics. These fields could benefit from novel experimental tools made possible by a future GF facility.
Mieczyslaw Witold Krasny
wiley +1 more source
Self-coherent optical transmission using a narrow linewidth tunable slotted fabry-perot laser [PDF]
A narrow linewidth slotted Fabry-Perot laser has been employed in a self-coherent optical transmission system. A comparison of the system performance of the tunable slotted laser with a SG-DBR laser has also been ...
Anandarajah, Prince M. +17 more
core +3 more sources
In this study, we present the optimization of a Fabry-Perot interferometer with a differential signal utilized as the laser encoder to meet the stringent demands of nanopositioning.
Syuan-Cheng Chang +2 more
doaj +1 more source

