Results 201 to 210 of about 59,535 (239)
Some of the next articles are maybe not open access.

Dynamic models of Fabry-Perot interferometers

Applied Optics, 2002
Long-baseline, high-finesse Fabry-Perot interferometers can be used to make distance measurements that are precise enough to detect gravity waves. This level of sensitivity is achieved in part when the interferometer mirrors are isolated dynamically, with pendulum mounts and high-bandwidth cavity length control servos to reduce the effects of seismic ...
David, Redding   +2 more
openaire   +2 more sources

High Sensitivity Humidity Fiber-Optic Sensor Based on All-Agar Fabry–Perot Interferometer

IEEE Sensors Journal, 2018
A high sensitivity humidity fiber sensor based on all-agar Fabry–Perot (FP) interferometer is proposed and experimentally demonstrated. The sensor is fabricated by filming a thin layer of moisture-sensitive agar to single mode fiber with end dipping ...
Bo Wang, Jiajun Tian, Ling Hu, Yong Yao
semanticscholar   +1 more source

High-sensitivity strain sensor with an in-fiber air-bubble Fabry-Perot interferometer

Applied Physics Letters, 2018
We present a laser machining method for fabricating an all-fiber pillar-in-bubble Fabry-Perot interferometer (FPI), which is used for strain sensors with high sensitivity. The micro-structure of the air-bubble is fully controllable, especially the cavity
K. Zhou   +12 more
semanticscholar   +1 more source

A scanning Fabry-Perot interferometer

Infrared Physics, 1978
Abstract A scanning Fabry-Perot interferometer has been constructed for balloon-borne observations at 156 μm. The semi-reflecting surfaces are tightly stretched, electroformed, metallic mesh. Spectral scanning is accomplished by mechanically changing the reflector separation via a moveable carriage sliding on linear ball bearings.
G. Chanin, J.C. Lecullier
openaire   +1 more source

A Scanning Fabry Perot Interferometer

Journal of Optics, 1983
A scanning Fabry Perot interferometer is made using a piezoelectric transducer tube (PZT) as a scanning element, and a photodiode as a detector. The paper gives the constructional details of the interferometer and also of the electronic circuit required for obtaining the scanning.
V. D. Dandawate   +2 more
openaire   +1 more source

Liquid-crystal based Fabry-Perot interferometer displacement sensor.

Applied Optics, 2019
A Fabry-Perot interferometer displacement sensor is proposed and demonstrated. This sensor is prepared by inserting two ceramic ferrules into a polydimethylsiloxane (PDMS) hose to generate a Fabry-Perot cavity.
Boyi Song   +6 more
semanticscholar   +1 more source

Low-Cost Fabry-Perot Interferometers

American Journal of Physics, 1965
This article describes the construction and use of Fabry-Perot devices for use in elementary laboratories. The basic ingredients are microscope cover glasses and inexpensive plate glass. The devices provide moderate resolving power (̃104) at almost no cost.
A. P. French, J. H. Smith
openaire   +1 more source

Double-Passed Fabry-Perot Interferometer

Journal of the Optical Society of America, 1961
Increased contrast and resolution can be obtained with the Fabry-Perot interferometer by reflecting the transmitted beams back through the instrument. An arrangement for this purpose is described in which the double-passed interference pattern is isolated by means of a simple polarizing system.
P. Hariharan, D. Sen
openaire   +1 more source

Fabry-Perot Interferometer Spectrometers

2009
The Fabry-Perot interferometer has been used as a spectrometer that has very high resolving power and large throughput, although it tends to have very little available field of view. It has, therefore, not been used much, if at all, as an imaging spectrometer. The limitations are described here.
openaire   +1 more source

A Fabry-Perot neutron interferometer

Physica B: Condensed Matter, 1991
Abstract Results of spectral measurements of a neutron multilayer interferometer are presented. The angular dependence of the reflectivity at wavelengths corresponding constructive and destructive interference have been investigated.
V.I. Mikerov   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy