Results 31 to 40 of about 2,067,785 (241)
Measurement of fluence at the D-line fast neutron facility at iThemba LABS [PDF]
Measurements of fluence were made for the neutron beams produced at the fast neutron beam facility of iThemba LABS, using an NE213 organic liquid scintillator detector and a 238U fission ionisation chamber.
Musonza, Emmanuel Tapiwa
core +1 more source
The present work examines two different geometric configurations and three different lining materials that are suitable for thermal neutron radiography purposes based on a 241Am/Be neutron source.
J.G. Fantidis
doaj +1 more source
Reactor test of beryllium as self-powered neutron detector emitter for fast neutron flux measurement [PDF]
Neutron flux in nuclear reactors causes damages to material components. Fast neutrons, above 1 MeV, modify mechanical and structural properties of materials.
Dupin Elsa +5 more
doaj +1 more source
In this study, thermal (2.53*10-8 MeV) and fast (2 MeV) neutron total macroscopic cross-sections of paraffin, polycarbonate, and polyester matrix polymers doped with B4C, B2O3, Sm2O3, and Gd2O3 (at weight percentages of 5%, 10%, 15%, 20%, and 25%) were ...
Yasin Gaylan +2 more
doaj +1 more source
The use of thermoluminescent dosimeters for In-vivo dosimetry in a fast neutron therapy beam [PDF]
Bibliography: leaves 72-77.Thermoluminescent detectors (TLD-700) have been investigated for absorbed dose measurements in a p(66)/Be neutron therapy beam at the National Accelerator Centre.
Bhengu, Khumbulani John
core +1 more source
Preliminary Study on Improving Resolution of D-T Neutron Radiography based on Associated Alpha and Coded Source Imaging Methods [PDF]
Limitations of fast neutron radiography include low detection efficiency and poor spatial resolution. D-T neutron radiography is one compact fast neutron radiography method.
Wang Sheng +7 more
doaj +1 more source
FNIT: the fast neutron imaging telescope for SNM detection [PDF]
We report on recent progress in the development of the Fast Neutron Imaging Telescope (FNIT), a detector with both imaging and energy measurement capabilities, sensitive to neutrons in the 2-20 MeV range.
James M. Ryan +21 more
core +1 more source
During fast neutron imaging, besides the dark current noise and readout noise of the CCD camera, the main noise in fast neutron imaging comes from high-energy gamma rays generated by neutron nuclear reactions in and around the experimental setup.
Di Zhang, Guomin Sun, Zihui Yang, Jie Yu
doaj +1 more source
Background: High-energy photons produced from a medical linear accelerator (LINAC) have long been used as one of the most effective ways for treating cancers.
Porama Thepsiri +5 more
doaj +1 more source
The cyclotron-based neutron sources and projects at NARI [PDF]
A compact accelerator-driven neutron source is being developed in Taiwan to fill the need in neutron scattering experimental facilities. The National Atomic Research Institute (NARI) is spearheading two neutron projects to deliver neutron services to ...
Jeng Sheng-Long +6 more
doaj +1 more source

