Results 161 to 170 of about 641,264 (308)

Sintering mode of a translucent Y-TZP: Effects on its biaxial flexure fatigue strength, surface morphology and translucency. [PDF]

open access: yesJ Esthet Restor Dent, 2022
Madruga CFL   +5 more
europepmc   +1 more source

Ultrasonic attenuation as an indicator of fatigue life of graphite/epoxy fiber composite [PDF]

open access: yes
The narrow band ultrasonic longitudinal wave velocity and attenuation were measured as a function of the transfiber compression-compression fatigue of unidirectional graphite/epoxy composites.
Doll, B., Williams, J. H., Jr.
core   +1 more source

Smart Catheters for Diagnosis, Monitoring, and Therapy

open access: yesAdvanced Healthcare Materials, EarlyView.
This study presents a comprehensive review of smart catheters, an emerging class of medical devices that integrate embedded sensors, robotics, and communication systems, offering increased functionality and complexity to enable real‐time health monitoring, diagnostics, and treatment. Abstract This review explores smart catheters as an emerging class of
Azra Yaprak Tarman   +12 more
wiley   +1 more source

FATIGUE STRENGTH ANALYSIS OF CONNECTING ROD BOLT FOR LARGE POWER DIESEL ENGINE

open access: yesJixie qiangdu, 2016
Diesel engine connecting rod bolt withstands pre-tightening force and tensile load in working process,its strength and stiffness have great effect on the performance.
LU YaoHui   +3 more
doaj  

Bone Healing Around Implants in Normal and Medically Compromised Conditions: Osteoporosis and Diabetes

open access: yesAdvanced Healthcare Materials, EarlyView.
xx xx. ABSTRACT Osseointegration of orthopedic and dental implants is influenced by local and systemic factors, including their physicochemical surface properties and the patient's overall health status. Titanium and its alloys have been a longstanding standard for bone implants due to their innate biocompatibility and mechanical properties.
Dainelys Guadarrama Bello   +2 more
wiley   +1 more source

Development of high-speed balancing technology [PDF]

open access: yes
An investigation into laser material removal showed that laser burns act in a manner typical of mechanical stress raisers causing a reduction in fatigue strength; the fatigue strength is lowered relative to the smooth specimen fatigue strength.
Demuth, R., Zorzi, E.
core   +1 more source

A Versatile Engineering Platform for the Fabrication of Prosthetic Venous Valves Using Electrospinning

open access: yesAdvanced Healthcare Materials, EarlyView.
Percutaneous prosthetic venous valves are fabricated by embedding stents in an electrospun matrix that extends luminally to form leaflets. The design shields leaflets from hyperplastic cells, isolates struts from blood contact, and avoids discrete anchoring points.
Dario Arcuti   +6 more
wiley   +1 more source