Results 31 to 40 of about 7,577,252 (286)
Controllable reactor based hybrid HVDC breaker
Short circuit fault occurrence in high-voltage DC (HVDC) systems causes extremely high currents in a fast raising time that does not experience current zero-crossing.
Amir Heidary +4 more
doaj +1 more source
The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis.
Yadong Liu +5 more
doaj +1 more source
Research on Access Mode of the Flexible DC Power Distribution System into AC System
The connection mode of the direct current (DC) power distribution system and the alternating current (AC) system is the foundation of system design, and it is also one of key technologies of the DC power distribution network.
Yao Liu +5 more
doaj +1 more source
A Practical Protection Coordination Strategy Applied to Secondary and Facility Microgrids
In a conventional distribution system, protection algorithms are designed to operate on a unidirectional high fault-current level. In a microgrid, a fault current from distributed generation (DG) may bring about a relay malfunction because of the ...
Woo-Kyu Chae +5 more
doaj +1 more source
ABSTRACT Background Loneliness is associated with adverse physical and mental health outcomes and remains understudied in children and adolescents undergoing cancer therapy. Pediatric oncology patients may be at increased risk due to medical isolation and disruption of social networks.
Charlotte N. Stahlfeld +5 more
wiley +1 more source
Vectorial Approach Based Control of a Seven-Phase Axial Flux Machine Designed for Fault Operation [PDF]
Version éditeur disponible à l'adresse suivante : http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4519973&isnumber=4636792This paper deals with easy-to-implement control strategies when a seven-phase axial flux permanent magnet machine supplied ...
LOCMENT, Fabrice +5 more
core +2 more sources
This paper presents a novel analytical method (NAM) of inductance identification for a direct drive permanent magnet synchronous motor (DDPMSM) with a stator winding fault (SWF), which considers the spatial position of the shorted turns.
Caixia Gao +4 more
doaj +1 more source
ABSTRACT Background Children with sickle cell anemia (SCA) in low‐income settings are at risk of severe malnutrition, but optimal nutritional management has not been established. We evaluated an intensified ready‐to‐use therapeutic food (RUTF) regimen in children with persistent severe malnutrition after initial treatment and assessed whether early ...
Safiya Gambo +9 more
wiley +1 more source
Capacitor banks are widely used in modern power systems for reactive power compensation and voltage regulation. However, switching operations of mechanically switched capacitors (MSCs) can generate transient phenomena, such as inrush currents, which may ...
Surakit Thongsuk +6 more
doaj +1 more source
Fault distance estimation-based protection scheme for DC microgrids
The DC microgrid has become a typical distribution network due to its excellent performances. However, a well-designed protection scheme still remains to be a challenge for DC microgrids.
Lin Zhang +3 more
doaj +1 more source