Distributed generation adverse impact on the distribution networks protection and its mitigation [PDF]
Integration of Distributed Generation (DG) generates problems for the protection of Distribution Networks (DNs) in power systems. When DG is integrated into a power distribution system (DS), the radial nature of the network is altered and the power ...
Haymanot Takele
doaj +2 more sources
Analisa Penggunaan Superconducting Fault Current Limiter (SFCL) Untuk Melindungi Peralatan di PT Pindo Deli [PDF]
Increas demand load and power capacity requirement at PT Pindo Deli then the short circuit current that occur will be greater. this can cause damage to electrical equipment located around the point of interrupting and resulting failure of the electrical ...
Yohanes Sabriant Widyo Utomo +1 more
doaj +2 more sources
Current–time characteristics of resistive superconducting fault current limiters [PDF]
Superconducting fault current limiters (SFCLs) may play an important role in power-dense electrical systems. Therefore, it is important to understand the dynamic characteristics of SFCLs.
Blair, Steven Macpherson +2 more
core +4 more sources
Optimal Allocation and Control of Superconducting Fault Current Limiter and Superconducting Magnetic Energy Storage in Mesh Microgrid Networks to Improve Fault Ride Through [PDF]
Voltage drop during the fault can be effected on the performance of generation units such as wind turbines. The ability to ride through the fault is important for these generation units.
A. Komijani +2 more
doaj +1 more source
A kind of DC fault current-limiter with instantaneous by-pass of current-limiting reactor [PDF]
With the rapid development of DC power grids, the protection of DC power grids is particularly important. Therefore, this paper proposes a kind of DC fault current-limiter with instantaneous by-pass of current-limiting reactance, analyses its working ...
Deng Jinyi, Li Chen, Gao Junfeng
doaj +1 more source
Research on a fault current limiter based on variable reactor
With the increase of the power load in power grid, the short circuit level continues to rise, and excessive short-circuit current will do great damage to power equipment and imperil power systems.
GU Yu +3 more
doaj +1 more source
Forces and Stresses in the Windings of a Superconducting Fault Current Limiter
This paper presents the design of a Superconducting Fault Current Limiter (SFCL) and calculation results of forces and stresses in the windings of a resistive fault current limiter.
Janusz Kozak
doaj +1 more source
Fault ride‐through strategy for hybrid HVDC with cascaded multi‐infeed MMC inverters
The hybrid HVDC with cascaded multi‐infeed MMC inverters suffers from the fragile characteristic of its MMC inverters and is easy to be over current and over voltage.
Jingbo Zhao +4 more
doaj +1 more source
Superconducting Surge Current Limiter
A superconducting fault current limiter (SFCL) for medium voltage networks cooled by a cryocooler was designed, built and tested by the current author. For the construction of this limiter, a high-temperature second generation superconducting tape (HTS ...
Sławomir Kozak
doaj +1 more source
Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability.
Md. Rashidul Islam +5 more
doaj +1 more source