Results 81 to 90 of about 2,329 (305)
Development of TCSC Application to Fault Current Limiters
AbstractA new Fault Current Limiter (FCL) is proposed which consists of a conventional Current Limiting Reactor (CLR) and a Thyristor‐Controlled Series Compensator (TCSC) in series. In normal operation, it works to compensate for impedance of the CLR and a line, while it limits short‐circuit currents during system faults.
Yuji Yamazaki +4 more
openaire +2 more sources
Operational control and protection implications of fault current limitation in distribution networks
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core
Impact of marine power system architectures on IFEP vessel availability and survivability
In recent years integrated full electric propulsion (IFEP) has become a popular power system concept within the marine community, both for the naval and the commercial community.
J.D. Schuddebeurs +7 more
core +1 more source
Beyond its role in immune evasion, this study identified that CD47 drives tumor‐intrinsic signaling in non‐small cell lung cancer (NSCLC). Transcriptomic profiling and functional studies revealed that CD47 regulates cell adhesion, migration, and metastasis through an ERK–EMT signaling axis.
Asa P.Y. Lau +8 more
wiley +1 more source
EXOSC10, an essential nuclear RNA exosome‐associated 3′‐5′ exoribonuclease, is inhibited by the anticancer drug 5‐fluorouracil (5‐FU), and EXOSC10 depletion increases 5‐FU sensitivity. The colon‐cancer variant EXOSC10S402T, located in a proteolysis motif, is stable and nuclear but nonfunctional in vivo.
Radhika Sain +10 more
wiley +1 more source
Thyristor based bridge‐type fault current limiter for fault current limiting capability enhancement
This study deals with a developed thyristor based bridge‐type fault current limiter (TBFCL), in which the main fault current limiting function is relegated to a limiting circuit controlled by a silicon controlled rectifier (SCR). Since SCR is a reliable power electronic switch and can be found in high ratings, the proposed TBFCL can be utilised in ...
Teymoor Ghanbari +2 more
openaire +1 more source
Intratumour heterogeneity complicates precision management of advanced endometrial cancer. Circulating tumor DNA (ctDNA) offers a minimally invasive strategy to capture tumor evolution and therapeutic resistance. Here, we compare tumor‐agnostic NGS with tumor‐informed ddPCR, outlining their relative sensitivity, concordance, and clinical implications ...
Carlos Casas‐Arozamena +15 more
wiley +1 more source
Quenched Flux-Coupling Superconducting Fault Current Limiter Scheme and Its Electromagnetic Design Method. [PDF]
Yan S +7 more
europepmc +1 more source
Design of a 10kV,500A Inductive Superconducting Fault Current Limiter
The design aspect of a 10kV,500A inductive superconducting fault current limiter was analyzed. The effect of the superconductor in the fault current limiter was defined. When placed in the system, in the absence of fault current,the superconducting fault
Akejelu, Daniel Limi
core
Here, we demonstrate that HS1BP3 interacts with Cortactin through a proline‐rich region (PRR3.1) and show that this interaction, and HS1BP3 itself, promote cancer cell proliferation and invasion. Inhibition of this interaction leads to build‐up of TKS5 in multivesicular endosomes and altered secretion of CD63 and CD9, providing an explanation for the ...
Arja Arnesen Løchen +9 more
wiley +1 more source