Results 221 to 230 of about 579 (264)

Development of a Disease Activity Index for the Assessment of VEXAS Syndrome (VEXAS‐DAI)

open access: yesArthritis Care &Research, Accepted Article.
Objective VEXAS syndrome is characterized by a complex spectrum of inflammatory and hematologic manifestations. Clinical research to identify effective therapies is urgently needed but is hindered by the lack of validated outcome measures. A VEXAS‐specific disease activity index (DAI) is an essential tool for reliably capturing changes in disease ...
Kevin Byram   +25 more
wiley   +1 more source

Multicell Fault Current Limiter

IEEE Transactions on Industrial Electronics, 2014
A multicell fault current limiter (MCFCL) is proposed in this paper. The MCFCL is composed of multiple fault current limiting cells. Each fault current limiting cell consists of a fault current limiting inductor and a power electronic module. The proposed MCFCL has the flexibility in expanding the operation voltage by increasing the number of fault ...
Wenyong Guo   +6 more
openaire   +1 more source

IGBT Fault Current Limiting Circuit

IEEE Industry Applications Magazine, 1995
Circuits are proposed which, by limiting the fault current magnitude, extends the short-circuit withstand time of high-efficiency (high-gain) IGBTs (insulated-gate bipolar transistors). Limiting of the fault current magnitude also results in reduced turn-off voltage transients, a desirable byproduct, especially for higher current modules. Moreover, the
R. Chokhawala, G. Castino
openaire   +1 more source

Nonsuperconducting Fault Current Limiter With Controlling the Magnitudes of Fault Currents

IEEE Transactions on Power Electronics, 2009
In this paper, a diode-bridge-type nonsuperconductor fault current limiter (NSFCL) is proposed. The structure has the capability of controlling the DC reactor current that yields to control the magnitude of fault current. In order to control the magnitude of DC reactor current, a discharging resistor is used in the proposed structure.
M.T. Hagh, M. Abapour
openaire   +1 more source

Fault Current Limitation Coordination in Electric Power Grid With Superconducting Fault Current Limiters

IEEE Transactions on Applied Superconductivity, 2018
This paper proposes the concept of “fault current limitation coordination” in a future electric power grid with multiple superconducting fault current limiters (SFCL). Not only the fault current limitation of each SFCL on a transmission line, but also the transient stability of the grid with SFCLs should be taken into account, because the disturbance ...
Naoki Hayakawa   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy