Results 261 to 270 of about 2,329 (305)
Some of the next articles are maybe not open access.

Fault Current Limitation Coordination in Electric Power Grid With Superconducting Fault Current Limiters

IEEE Transactions on Applied Superconductivity, 2018
This paper proposes the concept of “fault current limitation coordination” in a future electric power grid with multiple superconducting fault current limiters (SFCL). Not only the fault current limitation of each SFCL on a transmission line, but also the transient stability of the grid with SFCLs should be taken into account, because the disturbance ...
Naoki Hayakawa   +2 more
openaire   +1 more source

Comparison between resistive and inductive superconducting fault current limiters for fault current limiting

2012 Seventh International Conference on Computer Engineering & Systems (ICCES), 2012
Superconducting fault current limiters (SFCLs) are used to limit the short-circuit current level in electrical transmission and distribution networks. Applications of SFCLs would not only decrease the stress on network devices, but also can offer a connection to improve the reliability of power system.
Mohamed M. Aly, Emad A. Mohamed
openaire   +1 more source

Superconducting fault current limiters

IEE Colloquium on High Tc Superconducting Materials as `Magnets', 1995
Fault current limiters (FCLs), superconducting or otherwise, have the potential to reduce fault levels on electricity power networks, and may ultimately lead to lower rated components (i.e. cheaper) being used, or to increased capacity on existing systems.
openaire   +2 more sources

A superconducting fault-current limiter

Journal of Applied Physics, 1978
A conceptual design is presented for a fault-current limiter for the electrical power utilities which utilizes a superconducting element to commutate the fault current into a shunt resistor. The technical feasibility of the concept is supported by a computer simulation of the switching.
K. E. Gray, D. E. Fowler
openaire   +1 more source

Superconducting fault current limiters

IEEE Power Engineering Review, 2000
Events in the power utility industry, such as deregulation, demands for better power quality and reliability, the advent of high temperature superconductivity, and the push to use technology to realize greater profits, have renewed interest in fault current limiters (FCL).
openaire   +1 more source

Cognition on the current-limiting effect of saturated-core superconducting fault current limiter

2015 IEEE Magnetics Conference (INTERMAG), 2015
The saturated-core superconducting fault current limiter (SCSFCL) is an important facility for limiting the short-circuit fault current of the power grid. However, the cognition or the judgment on the current-limiting effect, which is the key indicator of the SCSFCL, is not unique.
Yuelong Jia   +5 more
openaire   +1 more source

Current Limiting Characteristics of Transformer Type Superconducting Fault Current Limiter

IEEE Transactions on Appiled Superconductivity, 2005
The transformer type superconducting fault current limiter is composed of a series transformer and a superconducting current limiting device. The primary winding of the transformer is connected in series to the power transmission line, and the secondary winding is short-circuited through the superconducting current limiting device whose normal ...
H. Yamaguchi   +4 more
openaire   +1 more source

Electromagnetic fault current limiter

Electric Power Systems Research, 1997
Abstract Due Due to electrical power system expansion, utility systems are faced with fault currents higher than the momentary and interrupting capabilities of the equipment installed. One method to solve the problem is to use a fault current limiter.
openaire   +1 more source

Current limiting level-time characteristic of a superconducting fault current limiter

Cryogenics, 1995
Abstract A model superconducting fault current limiter (SE-FCL) has been developed. The adopted superconducting cable is composed of six strands insulated from each other. The current limiting level of the SC-FCL is measured under two types of overcurrent, a sinusoidal and an inrush current.
Y.J. Tang   +5 more
openaire   +1 more source

An Ultrafast Fault Sensor for a Fault Current Limiting Device

IEEE Power Engineering Review, 1979
A power system fault current limiting device must act quickly if it is to limit the initial fault current.
I. Lee   +4 more
openaire   +1 more source