Results 91 to 100 of about 2,329 (305)

Interpreting the effects of DNA polymerase variants at the structural level

open access: yesMolecular Oncology, EarlyView.
Using MAVISp and molecular dynamics simulations, we analyzed over 60 000 missense variants in POLE and POLD1 from ClinVar, COSMIC, cBioPortal, and saturation mutagenesis. Identified mechanistic indicators, including stability, binding, and long‐range, enable structural interpretation, providing ACMG‐like evidence for possible reclassification of VUS ...
Matteo Arnaudi   +7 more
wiley   +1 more source

A voltage-clamped bidirectional fault current limiter based on a three-winding coupled inductor for DC power grids

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan   +4 more
doaj   +1 more source

Novel Topology of DC Energy-Released Circuit For Saturated-Core Fault Current Limiter

open access: yesIEEE Access, 2019
The saturated-core fault current limiter (SCFCL) has been studied by several scholars in the past decades. However, these studies have mainly focused on the AC coils of the SCFCL, the DC excitation has seldom been mentioned. In this paper, the DC coil of
Haocong Shen   +3 more
doaj   +1 more source

Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]

open access: yesPLoS One, 2021
Liu Y   +7 more
europepmc   +1 more source

HTS materials for AC current transport and fault current limitation

open access: yesIEEE Transactions on Appiled Superconductivity, 2001
The European SUPERPOLI project aims to define a MV fault current limiting power link, and to demonstrate its feasibility by a functional model. It includes the development of two alternative low-ac-loss conductor designs suitable for current limitation: a low-cost composite tubular Bi-2212 conductor with moderate Jc; and a coated tubular Y-123 ...
Verhaege, T.   +10 more
openaire   +3 more sources

Solid-state fault current limiter for medium voltage distribution systems

open access: yes, 2003
This paper presents a thyristor-controlled fault current limiter for medium voltage distribution systems (6-10 kV). The main goal of the proposed scheme is to alleviate the effect of the fault current on the switchgear and other equipment. The limiter is
Korobeynikov, Boris   +2 more
core   +1 more source

Circulating tumor cell viability during and after radiotherapy mirrors treatment response in cancer patients

open access: yesMolecular Oncology, EarlyView.
Radiotherapy (RT) response depends on the DNA repair capacity of tumor and host cells. We show that circulating tumor cell (CTC) counts and apoptosis rates before and after RT predict treatment response and outcome, which can be accessed via easily accessible liquid biopsy approaches. Created in BioRender. Wikman, H.
Yvonne Goy   +10 more
wiley   +1 more source

Study Of Superconducting Fault Current Limiter Using Saturated Magnetic Core

open access: yes, 2015
This paper presents a saturated magnetic core superconducting current limiter (SCSFCL) operation simulation results using finite element technique. The superconducting current limiter uses BSCCO tape to produce magnetic core saturation to increase the ...
Baldan C.A.   +3 more
core   +2 more sources

Superconducting Fault Current Limiter for the Electric Power System

open access: yes, 2016
Superconducting fault current limiters are the most attractive devices for the power network, they can be used to limit the short current in electrical network.
Majka, M., Kozak, J.
core   +1 more source

Home - About - Disclaimer - Privacy