Results 41 to 50 of about 2,329 (305)
DC fault clearance is one of the critical issues for the modular‐multilevel‐converter‐based high voltage direct current (MMC‐HVDC) systems. Employing a hybrid DC circuit breaker (H‐DCCB) to isolate the faulty line is a typical method to achieve fast ...
Pan Duan +3 more
doaj +1 more source
DC Fault Current Analyzing, Limiting, and Clearing in DC Microgrid Clusters
A new DC fault current limiter (FCL)-based circuit breaker (CB) for DC microgrid (MG) clusters is proposed in this paper. The analytical expressions of the DC fault current of a bidirectional interlink DC/DC converter in the interconnection line of two ...
Navid Bayati +5 more
doaj +1 more source
In this study, we found that human cervical‐derived adipocytes maintain intracellular iron level by regulating the expression of iron transport‐related proteins during adrenergic stimulation. Melanotransferrin is predicted to interact with transferrin receptor 1 based on in silico analysis.
Rahaf Alrifai +9 more
wiley +1 more source
Parallel-Resonance-Type Fault Current Limiter [PDF]
This paper proposes a new parallel-LC-resonance-type fault current limiter (FCL) that uses a resistor in series with a capacitor. The proposed FCL is capable of limiting the fault current magnitude near to the prefault magnitude of distribution feeder current by placing the mentioned resistor in the structure of the FCL. In this way, the voltage of the
Seyed Behzad Naderi +2 more
openaire +1 more source
Analysis of the DC Fault Current Limiting Characteristics of a DC Superconducting Fault Current Limiter Using a Transformer [PDF]
Recently, a lot of interesting research has been conducted to solve the fault current problem of the DC system. In long-distance transmission, DC transmission is more economical than AC transmission. The connection of power grids with a DC system can also better control the power flow and provide high stability.
Kang-Cheol Cho +2 more
openaire +2 more sources
Superconducting fault-current limiters (SFCLs) offer several benefits for electrical distribution systems, especially with increasing distributed generation and the requirements for better network reliability and efficiency.
Burt, Graeme +3 more
core +1 more source
Tau acetylation at K331 has limited impact on tau pathology in vivo
We mapped tau post‐translational modifications in humanized MAPT knock‐in mice and in amyloid‐bearing double knock‐in mice. Acetylation within the repeat domain, particularly around K331, showed modest increases under amyloid pathology. To test functional relevance, we generated MAPTK331Q knock‐in mice.
Shoko Hashimoto +3 more
wiley +1 more source
A Novel Self-Protective Transformer Using a Fault Current Limiter Approach
Transformers are essential components of distribution systems but are vulnerable to fault currents, posing significant challenges for their protection.
Sajjad Agheli +2 more
doaj +1 more source
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application.
Ho-Yun Lee +4 more
doaj +1 more source
Biomolecular condensates formed by fused in sarcoma (FUS) are dissolved by high ATP concentrations yet persist in cells. Using a reconstituted system, we demonstrate that valosin‐containing protein (VCP), an AAA+ ATPase, counteracts ATP‐driven dissolution of FUS condensates through its D2 ATPase activity.
Hitomi Kimura +2 more
wiley +1 more source