Results 81 to 90 of about 512,004 (238)

A voltage-clamped bidirectional fault current limiter based on a three-winding coupled inductor for DC power grids

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan   +4 more
doaj   +1 more source

HTS materials for AC current transport and fault current limitation

open access: yesIEEE Transactions on Appiled Superconductivity, 2001
The European SUPERPOLI project aims to define a MV fault current limiting power link, and to demonstrate its feasibility by a functional model. It includes the development of two alternative low-ac-loss conductor designs suitable for current limitation: a low-cost composite tubular Bi-2212 conductor with moderate Jc; and a coated tubular Y-123 ...
Verhaege, T.   +10 more
openaire   +3 more sources

Novel Topology of DC Energy-Released Circuit For Saturated-Core Fault Current Limiter

open access: yesIEEE Access, 2019
The saturated-core fault current limiter (SCFCL) has been studied by several scholars in the past decades. However, these studies have mainly focused on the AC coils of the SCFCL, the DC excitation has seldom been mentioned. In this paper, the DC coil of
Haocong Shen   +3 more
doaj   +1 more source

Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]

open access: yesPLoS One, 2021
Liu Y   +7 more
europepmc   +1 more source

Fault ride-through enhancement of fixed speed wind turbine using bridge-type fault current limiter

open access: yesJournal of Electrical Systems and Information Technology, 2016
The interaction between wind energy turbines and the grid results in two main problems, increasing the short-circuit level and reducing the Fault Ride-Through (FRT) capability during faults.
Mostafa I. Marei   +2 more
doaj   +1 more source

Behavior Of Superconducting Fault Current Limiter Under Fault Condition

open access: yes, 2017
Now a days due to increase in electricity demand for the purpose of industrialization, agriculture, domestic and educational etc there exists more chances of fault occurance. The Faults occurs due to insulation damaging, breaking of conductor, short circuit, lightning etc.
KARUNA L. BARI, S. M. SHEMBEKAR
openaire   +3 more sources

Improved Low Voltage Ride-Through Capability of DFIG with ESO Controller under Unbalanced Network Conditions

open access: yesMajlesi Journal of Electrical Engineering
Under unbalanced grid condition, in a Doubly-Fed Induction Generator (DFIG), voltage, current, and flux of the stator become asymmetric. Therefore, active-reactive power and torque will be oscillating.
Ali Akbar Vali   +2 more
doaj   +1 more source

A Thyristor-Based DC Fault Current Limiter With Inductor Inserting–Bypassing Capability

open access: yesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2019
DC fault current limiters (FCLs) are becoming increasingly important for the prompt dc fault clearance of modular multilevel converter (MMC)-based high-voltage direct current (HVdc) grids.
Jianzhong Xu   +4 more
semanticscholar   +1 more source

Optimal allocation of fault current limiters for sustaining overcurrent relays coordination in a power system with distributed generation

open access: yesAlexandria Engineering Journal, 2015
This paper addresses the problem of overcurrent relays (OCRs) coordination in the presence of DGs. OCRs are optimally set to work in a coordinated manner to isolate faults with minimal impacts on customers.
A. Elmitwally, E. Gouda, S. Eladawy
doaj   +1 more source