Results 31 to 40 of about 581 (260)

Association Between Dinutuximab Beta Exposure and Post‐End‐of‐Treatment Survival in Neuroblastoma: A Weighted Patient‐Level Analysis of Three Clinical Studies

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Objectives The association between exposure to dinutuximab beta (DB) and event‐free survival (EFS) or overall survival (OS) of neuroblastoma patients was assessed using data collected during three clinical trials (five cohorts). Methods A systematic review (March 2026) was conducted to identify relevant studies (prospective; registered DB ...
Przemysław Holko   +19 more
wiley   +1 more source

A Novel Self-Protective Transformer Using a Fault Current Limiter Approach

open access: yesIEEE Access
Transformers are essential components of distribution systems but are vulnerable to fault currents, posing significant challenges for their protection.
Sajjad Agheli   +2 more
doaj   +1 more source

Appropriate Protection Scheme for DC Grid Based on the Half Bridge Modular Multilevel Converter System

open access: yesEnergies, 2019
The half bridge (HB) modular multilevel converter (MMC) technology is considered a breakthrough to mitigate the shortcomings of the conventional voltage source converter (VSC) in high-voltage direct-current (HVDC) grid application.
Ho-Yun Lee   +4 more
doaj   +1 more source

Measurable Residual Disease Monitoring During Treatment for Pediatric Acute Myeloid Leukemia in First Relapse

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Survival after relapse in pediatric acute myeloid leukemia (AML) remains poor, highlighting the critical importance of identifying prognostic factors to guide optimal relapse management. Methods We investigated the prognostic impact of multiparameter flow cytometry (MFC) measurable residual disease (MRD) in 188 patients with first ...
Camilla Poulsen   +21 more
wiley   +1 more source

Magnetizing Characteristics of Bridge Type Superconducting Fault Current Limiter (SFCL) with Simultaneous Quench Using Flux-Coupling

open access: yesEnergies, 2020
A bridge type superconducting fault current limiter (SFCL) with simultaneous quench using two high-temperature superconducting (HTSC) elements and two coils was fabricated to analyze the fault current limiting characteristics.
Seok-Cheol Ko, Tae-Hee Han, Sung-Hun Lim
doaj   +1 more source

Inpatient Exposure, Confidence, and Knowledge in Pediatric Hematology/Oncology: Evaluating General Pediatric Residents During 2025 ACGME Curriculum Change

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background General pediatricians often evaluate hematologic and oncologic presentations before subspecialty consultation, yet the 2025 Accreditation Council for Graduate Medical Education (ACGME) pediatric requirements reduce inpatient pediatric hematology/oncology (PHO) time, raising questions about resident readiness.
Colburn Yu, Rohini Jain
wiley   +1 more source

A novel concept of fault current limiter based on saturable core in high voltage DC transmission system

open access: yesAIP Advances, 2018
To develop mechanical circuit breaker in high voltage direct current (HVDC) system, a fault current limiter is required. Traditional method to limit DC fault current is to use superconducting technology or power electronic devices, which is quite ...
Jiaxin Yuan   +7 more
doaj   +1 more source

Sociodemographic Factors Associated With Later Stage at Diagnosis of Pediatric Germ Cell Tumors: A Report From Children's Oncology Group Registries ACCRN07 and APEC14B1

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Germ cell tumors (GCTs) often arise in the ovaries and testes (extracranial) but can also develop in the brain (intracranial). We examined the relationship of individual, family, and community‐level socioeconomic status (SES) with stage of disease at diagnosis in a cohort of pediatric patients with GCT from Children's Oncology Group
Heydon K. Kaddas   +7 more
wiley   +1 more source

DC‐presaturated fault current limiter for high voltage direct current transmission systems

open access: yesHigh Voltage, 2021
The authors present a 500 kV real‐dimension DC‐presaturated fault current limiter (PFCL) with a steady‐state rated current of 2 kA for limiting large fault current of 8 kA with high rate of rise. These characteristics of the fault current can be a threat
Mohamed Eladawy   +2 more
doaj   +1 more source

Phase Angle as an Early Functional Biomarker of Cancer‐Related Fatigue in Pediatric Oncology: A Prospective Longitudinal Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Pediatric cancer remains a leading cause of morbidity and mortality worldwide, particularly in low‐and middle‐income countries. Cancer treatment may impair nutritional status, alter body composition, and exacerbate cancer‐related fatigue (CRF).
Luís Carlos Lopes‐Junior   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy