Investigation of the Performances of a Permanent Magnet Biased Fault Current Limiting Reactor with a Steel Core [PDF]
There is an increasing need in power system applications for fault current limiter, to limit the fault current in semiconductor devices and switchgear. These fault current limiters must be reliable, compact and inexpensive.
Iwahara, Masayoshi +7 more
core +2 more sources
New resonance type fault current limiter
This paper proposes a new parallel LC resonance type Fault Current Limiter (FCL). This structure has low cast because of using dry capacitor and non-superconducting inductor and fast operation.
Seyedbehzad Naderi (14745067) +2 more
core
A New Fault Current Limiter and its Application in Micro-Grid
In this paper, a new type fault current limiter (FCL) topology is put forward for Micro-Grid (MG) system fault, which mainly consists of limiting inductance, bypass inductance and series compensation capacitors.
Ying Jun Sang, Yuan Yuan Fan
core +1 more source
Distributed generation adverse impact on the distribution networks protection and its mitigation. [PDF]
Takele H.
europepmc +1 more source
Abstract In order to enhance the stability and reliability of the Photovoltaic-Energy storage-Direct-Flexible (PEDF) system, a novel line-compensation superconducting magnetic energy storage-fault current limiter (SMES-FCL) was designed to address voltage fluctuations and fault current limiting issues.
Baohua Liu +4 more
openaire +1 more source
Design and Experimental Study of a Novel Fault Current Limiter
Limiting the short-circuit current effectively is of great importance to keep the safe and steady running of the power system. A novel fault current limiter (FCL) on the basis of a high speed switch and a triggered vacuum switch (TVS) is presented.
Chun Zhao +4 more
core +1 more source
Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]
Liu Y +7 more
europepmc +1 more source
OVERCURRENT RELAY COORDINATION IN DISTRIBUTED GENERATION WITH FAULT CURRENT LIMITER
The distribution network has many advantages when it is connected to distributed generation (DG). Some problems in coordination of protection devices will occur in the presence of DG, due to change in short circuit level at different points.
Amit A. Chatte (5115593), Amit A. Chatte
core +1 more source
Protection of Sensitive Loads in Distribution Systems Using a BSFCL-DVR System. [PDF]
Firouzi M +4 more
europepmc +1 more source
Analysis and mitigation of PQ disturbances in grid connected system using fuzzy logic based IUPQC. [PDF]
Ravi T +4 more
europepmc +1 more source