Results 71 to 80 of about 8,810,376 (113)
Development of flux-lock-type fault current limiter with high-Tc superconducting element [PDF]
The present paper proposes a new type fault current limiter (FCL), which consists of a high Tc superconducting (HTS) element, three coils wound on the same core, and a magnetic field coil covering the HTS element.
Uchii, T. +5 more
core
Advancing energy integration: renewable sources, ancillary services, and stability. [PDF]
Gulraiz A +2 more
europepmc +1 more source
In this paper a variable and controllable resistor type fault current limiter (FCL) is introduced for enhancement of transient stability of single machine infinite bus (SMIB) system with a double circuit transmission line.
Seyedbehzad Naderi (14745067) +2 more
core
Bulk MgB2 Superconducting Materials: Technology, Properties, and Applications. [PDF]
Prikhna T, Sokolovsky V, Moshchil V.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Simulation of a Power Electronic Based Fault Current Limiter (FCL) in Case of Different Faults
2006 12th International Power Electronics and Motion Control Conference, 2006The effects of a Fault Current Limiter (FCL) on different types of faults in a three-phase network are presented in this paper. The FCL is based on a six-pulse thyristor rectifier with a freewheeling diode. Parallel to the three branches of the rectifier a further thyristor branch is added to handle faults with connection to earth.
G Herold
exaly +2 more sources
2005 European Conference on Power Electronics and Applications, 2005
The model of a fault current limiter (FCL) based on a six-pulse thyristor rectifier with a freewheeling diode is described in this paper. The FCL is connected to a transformer's neutral terminal. Furthermore the state space description and the calculation method are presented.
G Herold
exaly +2 more sources
The model of a fault current limiter (FCL) based on a six-pulse thyristor rectifier with a freewheeling diode is described in this paper. The FCL is connected to a transformer's neutral terminal. Furthermore the state space description and the calculation method are presented.
G Herold
exaly +2 more sources
A Novel Structure for Bridge-Type Fault Current Limiter: Capacitor-Based Nonsuperconducting FCL
IEEE Transactions on Power Electronics, 2018Taking into account extension of power systems, their interconnections, and increment of load demand, power capacity of networks is increased and the impedance of sources is decreased. Such variations in power systems resulted to occurring high ratings of fault currents.
Morteza Nazari-Heris +2 more
exaly +2 more sources
2016 24th Iranian Conference on Electrical Engineering (ICEE), 2016
Presence of distributed generations (DGs) is not without problem in distribution networks. In spite of their advantages these problems should also be solved. One of the most common problems is mismatching between fuse and recloser in temporary short circuits in presence of DGs. Hence, Fault Current Limiter (FCL) is used to solve the problem. The aim of
Sina Ghaemi
exaly +2 more sources
Presence of distributed generations (DGs) is not without problem in distribution networks. In spite of their advantages these problems should also be solved. One of the most common problems is mismatching between fuse and recloser in temporary short circuits in presence of DGs. Hence, Fault Current Limiter (FCL) is used to solve the problem. The aim of
Sina Ghaemi
exaly +2 more sources
Parallel-Resonance-Type Fault Current Limiter
This paper proposes a new parallel-LC-resonance-type fault current limiter (FCL) that uses a resistor in series with a capacitor. The proposed FCL is capable of limiting the fault current magnitude near to the prefault magnitude of distribution feeder ...
Mehdi Jafari, Mehrdad Tarafdar Hagh
exaly +2 more sources