Results 91 to 100 of about 7,559,493 (146)

Optimal Multiple FCLs Allocation Considering DG Penetration in Meshed Network With Multi-Level Voltages

open access: yesIranian Journal of Electrical and Electronic Engineering, 2020
Increasing the short circuit current due to the penetration of distributed generations (DGs) in various voltage levels and meshed topology is a basic problem in power systems.
M. Hosseinpour, J. Sadeh
doaj  

Coordinated Source-Grid fault current limiting strategy in HVDC grids based on fault severity and quantitative limitation demand

open access: yesInternational Journal of Electrical Power & Energy Systems
Reliable fault current limitation is critical in high-voltage direct current (HVDC) grids due to the fast dynamics and low fault tolerance of power electronic equipment, as well as the high cost of DC circuit breakers (DCCBs). To address these challenges,
Yuhong Wang   +5 more
doaj   +1 more source

Modification of Impedance Matrix and Short-Circuit Current Suppression in High-Proportion Wind Power Systems with Crowbar Activation

open access: yesShanghai Jiaotong Daxue xuebao
The short-circuit current characteristics of wind power generation systems represented by doubly-fed induction generators (DFIGs) differ from those of synchronous generators.
LIU Shengsong, XU Yunqing, CHEN Dawei, CAO Yi, WANG Shengbo, LIU Houru
doaj   +1 more source

Design of a 10kV,500A Inductive Superconducting Fault Current Limiter

open access: yes, 2017
The design aspect of a 10kV,500A inductive superconducting fault current limiter was analyzed. The effect of the superconductor in the fault current limiter was defined. When placed in the system, in the absence of fault current,the superconducting fault
Akejelu, Daniel Limi
core  

The impact of fault current limiter in power system performance [PDF]

open access: yes, 2009
Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers ...
Mohd. Ariff, Mohd. Aifaa   +1 more
core   +2 more sources

Using non-superconducting fault current limiter as inrush current limiter

open access: yes, 2011
In this paper, inrush current limitation of transformer using a bridge type fault current limiter (FCL) as inrush current limiter is proposed.
Seyedbehzad Naderi (14745067)   +2 more
core   +1 more source

非线性变压器理论在高压直流故障电流限制器中的应用研究

open access: yesGaoya dianqi, 2019
高压直流故障电流限制器(fault current limiter,FCL)是先进超导托卡马克装置系统中用于抑制短路电流,保护中性束注入系统的一种类变压器装置。文中从变压器铁心叠片的涡流损耗特性出发,采用分段线性插值的方法对FCL非线性磁滞回线模型进行优化,推导出非线性激磁电阻与电感的并联模型。通过仿真及实验的对比分析,结果表明优化磁滞回线模型仿真波形与试验结果吻合度高,短路电流抑制效果良好。
谢飞, 屈鲁, 金环
doaj  

Home - About - Disclaimer - Privacy