Results 11 to 20 of about 7,559,493 (146)
Implications of fault current limitation for electrical distribution networks [PDF]
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M. +11 more
core +4 more sources
The wind energy conversion technology of a Permanent Magnet Synchronous Generator (PMSG) is very promising in renewable power generation. However, the performance of the grid-connected PMSGs is greatly affected by grid disturbances because their stator ...
Kenneth E. Okedu, Kenneth E. Okedu
doaj +1 more source
Superconducting fault current limiter application in a power-dense marine electrical system [PDF]
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents.
Burt, Graeme +5 more
core +4 more sources
Operational control and protection implications of fault current limitation in distribution networks [PDF]
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core +3 more sources
Topology and control strategy of a multifunctional modular DC fault current limiter
DC fault current limiter (FCL) is a key device for suppressing DC short-circuit fault currents,which is important in AC/DC hybrid grid. In this paper,topology of a multifunctional modular DC FCL is proposed,which consists of multiple series-connected ...
ZHANG Liang +4 more
doaj +1 more source
A coordinated relay protection strategy of distribution network based on fault current limiting
In order to solve the problem of difficult coordination of traditional overcurrent relay protection caused by short supply radius and little difference of fault current along urban distribution network, a coordinated relay protection strategy based on ...
Qingpeng Zeng +5 more
doaj +1 more source
Current–time characteristics of resistive superconducting fault current limiters [PDF]
Superconducting fault current limiters (SFCLs) may play an important role in power-dense electrical systems. Therefore, it is important to understand the dynamic characteristics of SFCLs.
Burt, Graeme +2 more
core +4 more sources
Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability.
Md. Rashidul Islam +5 more
doaj +1 more source
The modular multilevel converter (MMC) topology is very suitable for high voltage direct current (HVDC) system to achieve feasible power control, favorable black start capability as well as long-distance power transmission.
Lei Chen +4 more
doaj +1 more source
The low voltage direct current (LVDC) distribution networks are connected with too many kinds of loads and sources, which makes them prone to failure.
Bing Han, Yonggang Li
doaj +1 more source

